4076
%1 Machine data could not be changed with permission level %2
Parameters:
%1 = Number of MDs
%2 = Preset access authorization
Explanation:
On executing a TOA file or when writing data from the part program an attempt has been made to write data with a higher
protection level than the access authorization currently set in the control. The data in question have not been written and
program execution is continued without hindrance. This alarm is issued on acknowledging alarm 4075. It can be cleared
only with Power ON.
On executing a TOA file an attempt has been made to write data with a higher protection level than the access authorization
currently set in the control.
The data in question have not been written.
This alarm is issued on acknowledging alarm 4075. It can be cleared only with Power ON.
Reaction:
NC Start disable in this channel.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Set the required access level by means of keyswitch or
password entry or delete the machine data concerned from the MD file/part program.
When entering a password, set the required access level or delete the corresponding machine data from the MD file.
Programm
continuation:
Switch control OFF - ON.
4077
New value %1 of MD %2 not set. Requested %3 bytes too much %4 memory.
Parameters:
%1 = New value of machine data
%2 = Machine data number
%3 = Number of bytes requested that exceeded availability
%4 = Type of memory
Explanation:
An attempt was made to enter a new value in the specified memory configuration machine data. It was not possible to
modify the value, as this would have cleared the contents of the user memory. This was because the memory requested
exceeded the available capacity.
The third parameter specifies the number of bytes by which the maximum user memory was exceeded.
The fourth parameter specifies the type of memory whose limit was exceeded.
- "D" stands for dynamic or non-buffered user memory (this is where, for example, the LUD variables are stored and the
interpolation buffer size is entered). The capacity of this memory type is defined by the current memory configuration and
the value in MD18210 $MN_MM_USER_MEM_DYNAMIC.
- "S" stands for static or buffered user memory (this is where part programs, offset data, R variables, tool data, etc. are
stored). This memory type is defined by the current memory configuration and the value in MD18230
$MN_MM_USER_MEM_BUFFERED.
- "iS" stands for internal static or buffered user memory. This memory type is defined by the current memory configuration
(not settable). A few NCK functions use this memory.
Reaction:
Alarm display.
Remedy:
If the modification was unintentional, ignore the error message and continue. The alarm has no negative effects. The
remedy depends on the access right and the current memory configuration of the NCK:
- The intended change is not possible -> Try again with a smaller value. Observe the change in the number of bytes.
- Is it possible to expand the memory? This option depends on the model in use. (Not possible if parameter 4 equals "iS").
- The NCK user memory may have been set smaller than it could be. With the appropriate access authorization, the
machine data (see above) can be changed.
- If parameter 4 equals "iS" and no synchronous actions are used, then MD18232
$MN_MM_ACTFILESYS_LOG_FILE_MEM[2] = 0 can be set. Otherwise the desired machine data change cannot be made.
Programm
continuation:
Clear alarm with the Delete key or NC START.
4080
Incorrect configuration of indexing axis in MD %1
Parameters:
%1 = String: MD identifier
Explanation:
The assignment of a position table to an indexing axis or the contents of a position table contains an error, or the length
of a position table has been parameterized with 0.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
59