6580
NC memory full
Explanation:
The NC card file system of the NCK is full. The task cannot be executed. To many files have been loaded
Reaction:
Alarm display.
Remedy:
Delete or unload files (e.g. parts programs)
Programm
continuation:
Clear alarm with the Delete key or NC START.
6581
NC user memory full
Explanation:
The DRAM file system of the user area is full. The order cannot be executed.
Reaction:
Alarm display.
Remedy:
Delete or unload files (e.g. parts programs)
Programm
continuation:
Clear alarm with the Delete key or NC START.
6582
NC machine OEM memory full
Explanation:
The DRAM file system of the machine OEM area is full. The order cannot be executed.
Reaction:
Alarm display.
Remedy:
Delete or unload files (e.g. parts programs)
Programm
continuation:
Clear alarm with the Delete key or NC START.
6583
NC system memory full
Explanation:
The DRAM file system of the system area (Siemens) is full. The order cannot be executed.
Reaction:
Alarm display.
Remedy:
Increase MD18354 $MN_MM_S_FILE_MEM_SIZE or, with Siemens cycles, increase the partition size in the cycle
ressource file.
Programm
continuation:
Clear alarm with the Delete key or NC START.
6584
NC memory limit TMP reached
Explanation:
The DRAM file system of the TMP (temporary) area is full. The job cannot be executed.
Reaction:
Alarm display.
Remedy:
Increase MD18351 $MN_MM_DRAM_FILE_MEM_SIZE or MD18355 $MN_MM_T_FILE_MEM_SIZE or switch off the
precompilation of individual or all cycles or delete files in the TMP area.
Programm
continuation:
Clear alarm with the Delete key or NC START.
6585
NC external memory limit reached
Explanation:
The DRAM file system of the external area (execution of the external drive) is full.
The job cannot be executed.
Reaction:
Alarm display.
Remedy:
Load the files to be executed explicitly into the NCK.
Programm
continuation:
Clear alarm with the Delete key or NC START.
6693
File %1 lost
Parameters:
%1 = File name
Explanation:
Due to a power failure, a file change could not be terminated properly. The file is lost.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
86