Reaction:
NC not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Import the file again.
Programm
continuation:
Switch control OFF - ON.
6694
Drives could not be mounted
Explanation:
The external drives could not be mounted within the configured time (see MD10128 $MN_EES_MAX_MOUNT_TIME).
Reaction:
NC not ready.
Interface signals are set.
Alarm display.
Remedy:
Check logdrives.ini and increase MD10128 $MN_EES_MAX_MOUNT_TIME if necessary.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
6700
[Channel %1: ] Value of the machine data %2%3 is too low
Parameters:
%1 = Channel number
%2 = MD identifier
%3 = If required, field index
Explanation:
The MD28302 $MC_MM_PROTOC_NUM_ETP_STD_TYP specifies the number of default event types for the protocol
users. However, more types are used than configured.
Reaction:
Alarm display.
Remedy:
Increase MD28302 $MC_MM_PROTOC_NUM_ETP_STD_TYP.
Programm
continuation:
Clear alarm with the Delete key or NC START.
7500
Block %1 invalid protection level for command %2 (protection level act.: %3 prog.: %4)
Parameters:
%1 = Block number
%2 = Programmed command
%3 = Current protection level of the command
%4 = Programmed protection level of the command
Explanation:
On assigning a protection level for a parts program command via REDEF command
- an impermissible parts program command has been programmed
- a protection level has been programmed that is logically smaller (larger in value) than the protection level currently
applicable for this command.
- the relevant definition file has not been protected sufficently against write access. The write protection of the file must be
at least as high as the highest protection level that has been assigned to a parts program command in this definition file.
Reaction:
Alarm display.
Remedy:
Modify definition files /_N_DEF_DIR/_N_MACCESS_DEF or /_N_DEF_DIR/_N_UACCESS_DEF-CESS_ DEF. Please see
the Siemens Programming Guide or the OEM documentation for the language commands permissible for the relevant
system configurations.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
8000
[Channel %1: ] Option 'Interrupt routines' not set
Parameters:
%1 = Channel number
Explanation:
Fast NCK inputs are required for the input signals in order to activate the interrupt routines and rapid lift from contour. This
function is not included in the basic version and must be retrofitted when needed.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
87