Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Define axis as interpolating axis (see MD30460 $MA_BASE_FUNCTION_MASK bit8) or change part program
Programm
continuation:
Clear alarm with the RESET key. Restart part program
8037
'Activate APC/Number of current setpoint filters' option not set.
Explanation:
More than six current setpoint filters were activated in the drive, although the corresponding option had not been set.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
- Buy option
- Deactivate the 'Advanced Positioning Control' (APC) function in the drive.
- Set a maximum of six current setpoint filters in the drive.
Programm
continuation:
Switch control OFF - ON.
8040
Machine data %1 reset, corresponding option is not set
Parameters:
%1 = String: MD identifier
Explanation:
A machine data has been set that is locked by an option.
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
For retrofitting the option, please refer to your machine manufacturer or to a sales representative of SIEMENS AG, A&D
MC.
Programm
continuation:
Clear alarm with the Delete key or NC START.
8041
Axis %1: MD %2, corresponding option not sufficient
Parameters:
%1 = Axis number
%2 = String: MD identifier
Explanation:
The number of axes specified in the associated option data has been exceeded.
More axes have been selected in the corresponding machine data than are permitted by the function associated with the
option.
The alarm can be reprogrammed in MD11412 $MN_ALARM_REACTION_CHAN_NOREADY (channel not ready).
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy:
Please inform the authorized personnel/service department.
- Increase option data
- Reduce number of axes
Programm
continuation:
Switch control OFF - ON.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
90
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2