Connecting the interfaces on the PPU
3.3.1
Digital input interfaces - X100, X101, X102
Type
Mini Combicon 10-pin
Cable
Max. length: 10 m
Max. cross-section:
One cable per connection:
≥ 0.5 mm2
Inputs
Permissible level (including ripple)
High level: 18 V - 30 V
Low level: -3 V - +5 V
Table 3- 1
Pin assignment of X100 (DIN0)
Illustration
Pin
Signal
Comment
1
N.C.
Not assigned
2
I0.0
Digital input
3
I0.1
Digital input
4
I0.2
Digital input
5
I0.3
Digital input
6
I0.4
Digital input
7
I0.5
Digital input
8
I0.6
Digital input
9
I0.7
Digital input
10
M
External ground