Power-On and Power-Up
5.3 Power-up
Manual
134
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
From 2nd power-up
The system responds as follows if it is powered up a second time with pending shutdown
signal:
●
Windows XP is not immediately shut down correctly.
●
NC and PLC are not started
●
The following message box appears:
6,180(5,.'LVO1&.3/&
$ODUP1&.VWDUWHGZKLOH3RZHU)DLOXUHVKXWGRZQZLWK2.
2.
This system response ensures that an error in the protection circuit of the MCI board
extension module or in the configuration of the shutdown signal does not result in an endless
loop (power-up > shutdown signal > power-up etc.).
As long as the message box has not been acknowledged the protective circuit of the MCI
board extension module and the configuration of the shutdown signal (see Section , "Menu:
Settings" (Page 490)) can be checked and changed, if necessary.
If the shutdown signal has been acknowledged from the message box, the NC and PLC are
started. Otherwise Windows XP is again shut down correctly.