Power-On and Power-Up
5.5 ServiceCenter
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
143
5.5.2
NC/PLC startup modes
Setting options
In the SINUMERIK 840Di sl-specific part of the ServiceCenter, you can specify the mode
that the NCK and PLC are to assume after startup. The following options can be set:
●
Start NCK and PLC
●
Do not start NCK and PLC
●
Start NCK and PLC in specified mode:
6,180(5,.'L1&.3/&
,I\RXZDQWWRFKDQJH1&.3/&VWDUWXSPRGH
VHOHFWZDQWHGPRGHDQGSUHVV2.
6WDUW1&.3/&
'RQRWVWDUW1&.3/&
6WDUW1&.3/&ZLWKPRGLILHGVZLWFKVHWWLQJV
1&.VZLWFK1RUPDO
3/&VZLWFK
6723
5813
581
6723
05(6FR0,
Figure 5-4
Start with PLC in the STOP mode (example)
NC modes
The following NCK modes can be set:
●
Normal
●
Loading standard machine data
After startup, the NC is in the reset state. All machine and user data are deleted and
standard machine data are loaded.
Note
You may have to consult your network administrator to obtain the above information or
any other information required for your current network.