PLC commissioning
6.3 Creating a SIMATIC S7 project
Manual
170
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
6.3.8
Parameterization of the communications processor (CP 840D sl) (Ethernet)
The following parameters must be set for parameterizing the integrated communications
processor "CP 840D sl":
●
IP address of the PCU
●
Subnet mask of the PCU
●
PCU gateway type
●
Subnet
Note
Determining the IP address and subnet mask of the PCU:
At the PCU: Windows XP taskbar: Start > Execute, command: ipconfig
By double-clicking the module
CP 840D sl, slot 5 in the 840Di sl-Rack, open the properties
dialog:
Dialog
Dialog: Properties - CP 840D sl
Tab: General
Group: Interface
Button: "Properties..."
Dialog: Properties - Ethernet interface CP 840D sl
Tab: Parameter
IP Address: <IP address of the PCU> (1)
Subnet mask: <Subnet mask of the PCU> (2)
Group: gateway
Option: Do not use router (3)
Group: Subnet
Button: "New..." (4)
Dialog: Properties - New subnet Ind. Ethernet
Name: <Name>
OK
OK
OK