Ethernet communication
7.5 MCP 483C IE
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
199
Input image
The following information is to be found in the table for each input bit:
●
1. Row: Default designation
●
2. Row: Key number (Sxy) or feedrate override switch (X30/X31), keyswitch (X50)
Table 7-2
Assignment of the key signals in the input image
Signals from machine control panel (keys)
Byte
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Spindle override
Mode
EB n+0
Override
Spindle8
X31.7
Override
Spindle4
X31.8
Override
Spindle2
X31.9
Override
Spindle4
X31.10
JOG
S01
TEACH
S04
MDA
S07
AUTO
S10
Machine functions
EB n+1
REPOS
S02
REF
S03
var. INC
S05
10000 INC
S12
1000 INC
S11
100 INC
S09
10 INC
S08
1 INC
S06
EB n+2
Key Pos. 0
X50.4
Key Pos. 2
X50.1
Spindle
Start
S48
*Spindle
Stop
S47
Feed start
S50
*Feed Stop
S49
NC Start
S16
*NC Stop
S15
Feed override
EB n+3
RESET
S13
Key Pos. 1
X50.6
Single
block
S14
Override
F.over.16
X30.6
Override
Feed 8
X30.7
Override
F.over.4
X30.8
Override
F.over.2
X30.9
Override
F.over.1
X30.10
Arrow keys
Axis selection
EB n+4
R15
S46
R13
S44
R14
S45
Key Pos. 3
X50.3
R1
S32
R4
S35
R7
S38
R10
S41
Axis selection
Axis selection
EB n+5
R2
S33
R3
S34
R5
S36
MKS/WKS
S43
R11
S42
R9
S40
R8
S39
R6
S37
Freely assignable customer keys
EB n+6
T9
S25
T10
S26
T11
S27
T12
S28
T13
S29
T14
S30
T15
S31
-
Freely assignable customer keys
EB n+7
T1
S17
T2
S18
T3
S19
T4
S20
T5
S21
T6
S22
T7
S23
T8
S24
EB n+8
-
-
-
-
-
-
-
-
EB n+9
-
-
-
-
-
-
-
-
EB n+10
-
-
-
-
-
-
-
-
EB n+11
-
-
-
-
-
-
-
-
EB n+12
-
-
-
Override
spindle16
Override
spindle8
Override
spindle4
Override
spindle2
Override
spindle1
* Inverse transferred signals signals
- free signals
Note
Free signals are transferred from the MCP with 0.