PROFIBUS DP Communication
8.6 DP slave MCP 310
Manual
256
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Display of the software version
All the LEDs on the front panel of the MCP flash after the electrical connection of the MCP,
provided there is no communication between MCP and PLC.
Simultaneously pressing the two keys "Feed stop" and "Feed enable" (in the bottom right
corner) displays the version number of the current software version using the LEDs which
are now illuminated continuously.
Version No. = V
"No. of glowing LEDs in the left LED block".
"No. of glowing LEDs of the middle LED block".
"Number of glowing LEDs in the right LED block"
In the example (see Figure. Subsection "Parameterization of the MCP) V 01.02.00 is
displayed.