Drive commissioning (SINAMICS)
9.2 ONLINE commissioning
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
309
9.2
ONLINE commissioning
Installation variant 1: STARTER and SIMATIC STEP 7
If the SINAMICS drive commissioning tool STARTER and SIMATIC STEP7 are installed
together on the same programmable controller (PG/PC or PCU of SINUMERIK 840 Di sl),
then the STARTER can be started either directly or from a SINAMICS STEP 7 project.
Start STARTER directly
If the STARTER is started directly (e.g. via the Windows taskbar Start > SIMATIC > STEP 7
> STARTER), then a new project must be created in the STARTER for executing the drive
startup. To do this, continue with Section Create new project with Project Wizard (Page 313).
Start STARTER from STEP 7
If the STARTER is started from a SINAMICS STEP 7 Project (See following figure: Double-
click on the drive object in the detail view of the SIMATIC Manager), one can start
immediately with the automatic detection of the component topology and the configuration.
To do this, continue with Section Drive unit: Enter component topology and configuration
automatically. (Page 316).
7&3,3!5HDOWHN75/
3UHVV)WRRSHQWKHKHOS
1RILOWHU!
6,1$0,&6B6
6,1$0,&6B6B&8
&3'VO
3/&'3$-
6,0$7,&
)LOH(GLW,QVHUW7DUJHW6\VWHP9LHZ7RROV:LQGRZ+HOS
6,1'LVO
6,0$7,&0DQDJHU6,1'LVO
Installation variant 2: STARTER without SINAMICS STEP 7
If the SINAMICS drive commissioning tool STARTER is installed without SIMATIC STEP 7
on a programmable controller (PG/PC or PCU of the SINUMERIK 840Di sl), the STARTER is
started directly (e.g. via the Windows taskbar Start > SIMATIC > STEP 7 > STARTER). After
that a new project must be created and the online connection data must be set in the
STARTER for executing the drive startup. To do this, continue with Section Create new
project without Project Wizard (Page 310)
See also