Drive commissioning (SINAMICS)
9.2 ONLINE commissioning
Manual
314
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
3.
Set the PG/PC interface if required and test whether all SINAMICS drive units connected
to the PROFIBUS which are to be commissioned as part of this project are accessible via
the PG/PC interface. To go to the corresponding dialog box, click the "Change and
test...." button.
Note
The stations accessible via the PG/PC interface are displayed in the SIMATIC NET
diagnostic screen.
Then click the "Continue >" button: