Drive commissioning (SINAMICS)
9.2 ONLINE commissioning
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
317
2.
After the online connection to the drive unit has been established, click the "Restore
factory settings" button:
3URMHFW(GLW7DUJHW6\VWHP9LHZ7RROV:LQGRZ+HOS
67$57(53URMHFW
'ULYHB8QLWB$GGU
$GGLQGLYLGXDOGULYH
3URMHFW
●
Confirm the following dialog with OK to restore the factory settings.
1.
Double-click "Automatic configuration" in the project navigator.
The navigator then searches for all components connected to the drive unit and loads
these into the STARTER.
3URMHFW(GLW7DUJHW6\VWHP9LHZ7RROV:LQGRZ+HOS
67$57(53URMHFW
2YHUYLHZ
&RQILJXUDWLRQ
$XWRPDWLFFRQILJXUDWLRQ
7RSRORJ\
'ULYHB8QLWB$GGU
$GGLQGLYLGXDOGULYH
3URMHFW
2.
In the next dialog box "Automatic configuration", click on the "Start automatic
configuration" button.
Select the Servo type in the next dialog box "Drive object type" and click on the "Finish"
button.
The following note lists the drives that require offline motor configuration because the
corresponding data cannot be determined online. Confirm with OK.
Note:
Motors with DRIVE CliQ interfaces do not require subsequent offline configuration as the
appropriate parameters can be determined online by the STARTER.
3.
To close, click the "Close" button in the "Automatic Configuration" dialog.