Drive commissioning (SINAMICS)
9.3 Example for systems with more than 6 drives
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
333
9.3
Example for systems with more than 6 drives
9.3.1
Configuration
One control unit CU 320 can control max. 6 drives in "Servo" mode. The following example
shows which drive components are required and how they are interconnected to operate
more than 6 drives in one configuration.
Requirement:
●
Control of 9 drives in "Servo" mode.
Components used:
●
1. Control Unit: CU320 (Control_Unit_1)
●
2. Control Unit: CU320 (Control_Unit_2)
●
Infeed: Active Line Module (ALM)
●
Power module 1: Single Motor Module (SMM), (Drive_1)
●
Power module 2: Double Motor Module (DMM), (Drive_2 and Drive_3)
●
Power module 3: Double Motor Module (DMM), (Drive_4 and Drive_5)
●
Power module 4: Double Motor Module (DMM), (Drive_6 and Drive_7)
●
Power module 5: Double Motor Module (DMM), (Drive_8 and Drive_9)
●
Sensor module 1-9: Sensor Module Cabinets (SMC) (not shown)
●
Motor 1-9: Standard motor without DRIVE-CliQ connection (not shown)
'5,9(ದ&/L4FRQQHFWLRQWR
HDFKVHQVRUPRGXOH
&8
&B8B
$/0
600
'00
'00
'00
'00
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
&8
&B8B
$/0
'ULYHB
'ULYHB
'ULYHB
'ULYHB
'ULYHB
'ULYHB
'ULYHB
'ULYHB
'ULYHB
Figure 9-5
Example configuration for 9 drives