Drive commissioning (SINAMICS)
9.3 Example for systems with more than 6 drives
Manual
336
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
0
',
'2
;
0HDVXULQJVRFNHWV
%LGLUHFWLRQDOGLJLWDOLQSXWVRXWSXWV
,QSXW
'LJLWDOLQSXWV
,QIHHGU%LW&2%2
2XWSXW
Figure 9-8
STARTER: Work area (excerpt)
3.
Via a BICO interconnection, connect to Control_Unit_2 the parameter "r722: Bit0. CO/BO:
CU digital inputs, status: :DI 0" of the input terminal: "DI 0" (X122.1), Project > Drive
unit_Adr10 > Control_Unit_1 > Double-click on "inputs/outputs" > Tab "Digital inputs" >
Digital input 0 (1) for all drives of Control_Unit_2 with the parameter "p864, BI: Infeed
operation (2).
',
',
',
',
;
S>@%,(QDEOHVWKHUDPSದIXQFWLRQJHQHUDWRU
'ULYHB
'ULYHB
'ULYHB
&RQWUROB8QLWB
'ULYHB
)XUWKHULQWHUFRQQHFWLRQV
S>@%,(QDEOHRSHUDWLRQ
'LJLWDOLQSXW
0HDVXULQJVRFNHWV
%LGLUHFWLRQDOGLJLWDOLQSXWVRXWSXWV
'LJLWDOLQSXWV
'ULYHBS%,,QIHHG
S%,,QIHHGRSHUDWLRQ
Figure 9-9
STARTER: Work area (excerpt)
4.
Connect the output terminal "DO 8" (X122.7) of Control_Unit_1 to the input terminal "DI 0"
(X122.1) of Control_Unit_2 via an external interconnection.
5.
The output terminal of Control_Unit_1 must be wired to an input terminal of
Control_Unit_2.
6.
The input terminal of Control_Unit_2 is to be connected via the BICO interconnection with
the driver parameters "p864 BI: Infeed operation" to all the drives of Control_Unit_2.
7.
There is no DRIVE CliQ connection between the infeed and Control_Unit_2.