SimoCom U: 12-digit S7 subnet ID:
Determine PROFIBUS S7 subnet ID
If you do not have the PROFIBUS S7 subnet ID, you can call it using the SIMATIC Manager
STEP 7.
To do so, proceed as follows:
●
Open the appropriate S7 project in the SIMATIC Manager S7.
●
Select the appropriate station (in the example project: SIMATIC 300)
●
Open the hardware configuration of the station (double-click with left mouse button on:
Hardware; "HW Config" will be started)
●
Open DP master (in the example project: DP master) (double-click with left mouse button
on DP master)
●
You will find the subnet ID as follows using the Properties dialog box of the DP master:
Dialog
Dialog: Properties - DP master
Tab: General
Group: Interface
Type: PROFIBUS
address: 2
Button: "Properties..."
Dialog: Properties - PROFIBUS interface DP master:
Tab: Parameter
Subnet: PROFIBUS
Button: "Properties..."
Dialog: Properties PROFIBUS
Tab: General
S7 subnet ID: 0010 - 0005 (Please note, example only)
Cancel
Cancel
Cancel
The online operation with the drives connected to PROFIBUS can now be started.