NC Commissioning with HMI Advanced
11.4 Memory configuration
Manual
384
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Machine data
Table 11-13 Machine data required to configure the SRAM
Number
Name
Name/remarks
General ($MN_ ... )
18060
INFO_FREE_MEM_STATIC
Display data of the free static memory
18080
MM_TOOL_MANAGEMENT_MASK
Screen form for reserving memory for the tool management
18082
MM_NUM_TOOL
Number of tools managed by NC
18084
MM_NUM_MAGAZINE
Number of magazines managed by NC
18086
MM_NUM_MAGAZINE_LOCATION
Number of magazine locations
18090
MM_NUM_CC_MAGAZINE_PARAM
Compile cycles of tool management: Number of magazine data
18092
MM_NUM_CC_MAGLOC_PARAM
Compile cycles of tool management: Number of magazine
location data
18094
MM_NUM_CC_TDA_PARAM
Compile cycles of tool management: Number of TDA data
18096
MM_NUM_CC_TOA_PARAM
Compile cycles of tool management: Number of TOA data
18098
MM_NUM_CC_MON_PARAM
Compile cycles of tool management: Number of monitor data
18100
MM_NUM_CUTTING_EDGES_IN_TOA
Number of tool offsets
18118
MM_NUM_GUD_MODULES
Number of GUD modules
18120
MM_NUM_GUD_NAMES_NCK
Number of global user variables
18130
MM_NUM_GUD_NAMES_CHAN
Number of channel-specific user variables
18140
MM_NUM_GUD_NAMES_AXIS
Number of axis-specific user variables
18150
MM_GUD_VALUES_MEM
Memory reserved for global user variables
18160
MM_NUM_USER_MACROS
Number of macros
18190
MM_NUM_PROTECT_AREA_NCK
Number of protection areas
18230
MM_USER_MEM_BUFFERED.
User memory in SRAM
18270
MM_NUM_SUBDIR_PER_DIR
Number of subdirectories
18280
MM_NUM_FILES_PER_DIR
Number of files per directory
18290
MM_FILE_HASH_TABLE_SIZE
Hash table size for files in a directory
18300
MM_DIR_HASH_TABLE_SIZE
Hash table size for subdirectories
18310
MM_NUM_DIR_IN_FILESYSTEM
Number of directories in passive file system
18320
MM_NUM_FILES_IN_FILESYSTEM
Number of files in passive file system
18330
MM_CHAR_LENGTH_OF_BLOCK
Max. length of an NC block
18350
MM_USER_FILE_MEM_MINIMUM
Minimum NC program memory
28050
MM_NUM_R_PARAM
Number of channel-specific R parameters
28080
MM_NUM_USER_FRAMES
Number of settable frames
28085
MM_LINK_TOA_UNIT
Allocation of a TO unit to a channel
28200
MM_NUM_PROTECT_AREA_CHAN
Number of modules for channel-specific protection zones
Axisspecific ($MA_ ... )
38000
MM_ENC_COMP_MAX_POINTS
Number of intermediate points with interpolatory compensation