NC Commissioning with HMI Advanced
11.5 Axes and spindles
Manual
404
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
(QFRGHUV
&\FOHV\QFKURQLVDWLRQ
&RQILJXUDWLRQ
*HQHUDO
$[LV0HVVDJH)UDPH3='
&RQVLVWHQF\
8QLW
/HQJKW
,2$GG
35
7\SH
$GGU
7\SH
7RWDO/HQJWK
:RUG
2XWSXW
3'$
7RWDO/HQJWK
:RUG
,QSXW
3'$
$FWXDO9DOXH
6HWSRLQW
1R3.:
'ULYH
352),%863DUWQHU
6ORW
'3VODYHN3URSHUWLHV
Figure 11-13 DP slave properties: SIMODRIVE 611U
ADI4:
●
Message frame type: Standard message frame 3
●
I/O address: 4200
'3VODYHSURSHUWLHV
*HQHUDO
($$GGU
35
3='
3='
&RQVLVWHQF\
8QLW
/HQJWK
7\SH
$GGU
7\S
7RWDOOHQJWK
:RUG
2XWSXW
7RWDOOHQJWK
:RUG
,QSXW
$FWXDOYDOXH
6HWSRLQW
1R3.:
'ULYH
352),%86SDUWQHU
6ORW
D[HVHDFKZLWKRQHHQFRGHUVWDQGDUGPHVVDJHIUDPH($3='$
&RQILJXUDWLRQ
&\FOHV\QFKURQL]DWLRQ (QFRGHU
Figure 11-14 DP slave properties: ADI4
NC machine data
The general and axis-specific NC machine data should be set as follows:
Drive assignment:
The axis of the SIMODRIVE 611U drive module is assigned to the NC as the 1st machine
axis. This requires entry of its I/O address and message frame type under index 0:
●
MD13050 $MN_DRIVE_LOGIC_ADRESS[0] = 4100
●
MD13060 $MN_DRIVE_TELEGRAM_TYPE[0] = 102
The I/O address and the message frame type of the 1st axis of the ADI4 module will be
entered in the next free machine data (e.g. Index 3):
●
MD13050 $MN_DRIVE_LOGIC_ADRESS[3] = 4200
●
MD13060 $MDRIVE_TELEGRAM_TYPE[3] = 3
Assignment of the actual value channels:
Assignment of the 1st measuring system (index 0) of the machine axis to the measuring
circuit input of the SIMODRIVE 611U drive module is performed via the axis-specific
machine data:
●
MD30220 $MA_ENC_MODUL_NR[0] = 1
with 1 = (Index 0 of the corresponding M 1)