NC Commissioning with HMI Advanced
11.5 Axes and spindles
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
423
Setting data
Table 11-36 Velocities: Setting data
Number
Name
Name/remarks
General ($SN_ ...)
41100
JOG_REV_IS_ACTIVE
Revolutional feedrate in JOG mode active
41110
JOG_SET_VELO
JOG velocity for linear axes (for G94)
41120
JOG_REV_SET_VELO
JOG velocity (for G95)
41130
JOG_ROT_AX_SET_VELO
JOG velocity for rotary axes
41200
JOG_SPIND_SET_VELO
JOG velocity for the spindle
References:
/FB/ Function Manual - Basic Functions; G2 Velocities, Setpoint/Actual Value Systems,
Control, Section "Velocities, Traversing Ranges, Accuracies"
/FB/ Function Manual - Extended Functions, H1 Manual and Handwheel Travel
11.5.18
Axis monitoring
Static monitoring functions
The static monitoring functions with reference to a machine axis are:
Exact stop coarse
Window around the setpoint position within which exact stop coarse is detected.
●
MD36000 $MA_STOP_LIMIT_COARSE (exact stop coarse)
●
IS DB31,... DBX60.6 (position reached with exact stop coarse)
Exact stop fine
Window around the setpoint position within which exact stop fine is detected.
●
MD36010 $MA_STOP_LIMIT_FINE (exact stop fine)
●
IS DB31,... DBX60.7 (position reached with exact stop coarse)
Delay time exact stop fine
Delay time after which the actual value must have reached the tolerance window "Exact stop
fine" when the setpoint position is reached.
●
MD36020 $MA_POSITIONING_TIME (delay time exact stop fine)
●
Alarm "25080 Positioning monitoring" and follow-up mode.