NC Commissioning with HMI Advanced
11.5 Axes and spindles
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
455
Encoder limit frequency
If the sensor limit frequency in the following machine data is exceeded, synchronization of
the spindle is lost and spindle functionality is reduced (thread, G95, G96):
●
MD36300 $MA_ENC_FREQ_LIMIT (encoder limit frequency)
The spindle will be re-synchronized automatically once the sensor frequency falls below the
value defined in the following machine data:
●
MD36302 $MA_ENC_FREQ_LIMIT_LOW (encoder limit frequency at which the encoder
is turned on again).
The encoder limit frequency value must be such that the mechanical encoder speed limit is
not exceeded or else the synchronization from high speeds will be incorrect.
0D[YHORFLW\VSHHGಯ$[LVVSLQGOHVWRSSHGರ
3URJUDPPDEOHVSLQGOHVSHHGOLPLJ*
3URJUDPPDEOHPLQQLPXPVSLQGOHVSHHG*
3URJUDPPDEOHVSLQGOHVSHHGOLPLW/,06
0D[LPXPVSLQGOHVSHHGIRUFXUUHQWJHDUVWDJH
0LQLPXPVSLQGOHVSHHGIRUFXUUHQWJHDUVWDJH
0D[LPXPVSLQQGOHVSHHG
0D[LPXPHQFRGHUOLPLWIUHTXHQF\
6SHHGFRQWUROHU
,6$[LV6SLQGOHVWDWLRQDU\QPLQ
6SHHGUDQJHRIVSLQGOHRUVSLQGOHFKXFN
6SHHGUDQJHRIFXUUHQWJHDUVWDJH
6SHHGUDQJHRIFXUUHQWJHDUVWDJHOLPLWHGE\
*DQG*
6SHHGUDQJHRIFXUUHQWJHDUVWDJHZLWKFRQVWDQW
FXWWLQJUDWH*DQG*
,65HIHUHQFHGV\QFKURQL]HG
Figure 11-30 Ranges of spindle monitoring functions/speeds
References:
/FB1/ Function Manual - Basic Functions, S1 Spindles, Chapter "Spindle Monitoring"