NC Commissioning with HMI Advanced
11.6 Handwheels
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
465
Operator component interface ->
MCP1
MCP2
HHU
Handwheel interface
1)
1
2
1
2
1
2
FB1 Parameter
2)
MCP1BusAdr
MCP2BusAdr
BHGRecGDNo
Assignment of the handwheels
3)
MCP 483C IE
X60
X61
X60
X61
-
-
HT 8
x
-
x
-
-
-
HT 2
-
-
-
-
x
-
Handwheel interface at the Ethernet bus (y)
4)
-
>
1
2
3
4
5
6
1) Numbering of the handwheel interfaces within an operator component interface
2) Assignment of the operator component interface to the interface via the corresponding FB1 parameter
3) Assignment of the handwheels of the respective operator components to the handwheel interfaces
4) Numbering of the handwheel interfaces at the Ethernet bus -> MD11352 $MN_HANDWHEEL_INPUT[< x - 1 >] = y
Example
Parameterization of 3 handwheels, connected via the following operator components:
Operator component interface ->
MCP1
MCP2
HHU
Operator components
HT 8
MCP 483C
HT 2
FB1 parameters
MCP1BusAdr := 39
MCP2BusAdr := 192
BHGRecGDNo := 40
Handwheel interface
x
-
-
X61
x
-
Handwheel interfaces at Ethernet Bus ->
1
2
3
4
5
6
Table 11-52 NCK machine data for the handwheel assignment
Machine data
Value
Description
HT 8: Handwheel number in the NC = 1
MD11350 $MN_HANDWHEEL_SEGMENT[ 0 ]
7
Segment: Ethernet
MD11350 $MN_HANDWHEEL_MODULE[ 0 ]
1
Module: Ethernet
MD11350 $MN_HANDWHEEL_INPUT[ 0 ]
1
Handwheel interface at Ethernet Bus
MCP 483C IE: Handwheel number in the NC = 2
MD11350 $MN_HANDWHEEL_SEGMENT[ 1 ]
7
Segment: Ethernet
MD11350 $MN_HANDWHEEL_ MODULE [ 1 ]
1
Module: Ethernet
MD11350 $MN_HANDWHEEL_ INPUT [ 1 ]
4
Handwheel interface at Ethernet Bus
HT 2: Handwheel number in the NC = 3
MD11350 $MN_HANDWHEEL_SEGMENT[ 2 ]
7
Segment: Ethernet
MD11350 $MN_HANDWHEEL_ MODULE [ 2 ]
1
Module: Ethernet
MD11350 $MN_HANDWHEEL_ INPUT [ 2 ]
5
Handwheel interface at Ethernet Bus