NC Commissioning with HMI Advanced
11.7 Digital and analog I/O devices
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
467
11.7
Digital and analog I/O devices
The following digital and analog signal modules are available:
Digital I/O modules
●
MCI board extension module (option)
There are 4 digital inputs/outputs in each MCI board extension module (option) (Section
"MCI board extension slot variant" (Page 56)).
●
PP 72/48
The I/O module PP 72/48 has 72 digital inputs and 48 digital outputs (Section "Device
●
ADI4
The ADI4 has two digital input and output bytes that are used for ADI4-internal functions
and as I/O signals at the interfaces of the module (Chapter "ADI4 (Analog Drive Interface
●
SIMATIC S7: ET200 modules
Via the PROFIBUS DP, it is possible to connect all subtypes of SIMATIC-S7 I/O modules
of type ET200 (e.g. ET200M) as long as they support a data transmission rate of 12
Mbaud.
Analog I/O modules
●
SIMATIC S7: ET200 modules
See above.
NOTICE
The digital and analog inputs/outputs connected via the PROFIBUS DP are equally
available to both the NC and PLC.
It is the sole responsibility of the user to avoid access conflicts:
•
NC side: Part program/synchronized action
•
On the PLC side: PLC user program
References:
/FB/ Function Manual for Extended Functions, A4 Digital and Analogue NC I/Os