NC Commissioning with HMI Advanced
11.7 Digital and analog I/O devices
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
477
Number
Name
Name
10530
COMPAR_ASSIGN_ANA_INPUT_1
Hardware assignment of NC analog inputs for comparator byte
1
10531
COMPAR_ASSIGN_ANA_INPUT_2
Hardware assignment of NC analog inputs for comparator byte
2
10540
COMPAR_TYPE_1
Parameterization for comparator byte 1
10541
COMPAR_TYPE_2
Parameterization for comparator byte 2
Channelspecific ($MC_ ... )
21220
MULTFEED_ASSIGN_FASTIN
Assignment of input bytes of NC I/Os for "multiple feedrates in
one block"
Setting data
Table 11-55 Digital and analog I/Os: Setting data
Number
Name
Name
General ($SN_ ...)
41600
COMPAR_THRESHOLD_1
Threshold values for comparator byte 1
41601
COMPAR_THRESHOLD_2
Threshold values for comparator byte 2
Interface signals
Table 11-56 Digital and analog I/Os: Interface signals
DB number
Bit, byte
Name
General
Signals from PLC to NC
10
0, 122, 124, 126, 128
Disable digital NC inputs
10
1, 123, 125, 127, 129
Setting on PLC of digital NC inputs
10
4, 130, 134, 138, 142
Disable digital NC outputs
10
5, 131, 135, 139, 143
Overwrite mask for digital NC outputs
10
6, 132, 136, 140, 144
Setting value from PLC for the digital NC outputs
10
7, 133, 137, 141, 145
Setting mask for digital NC outputs
10
146
Disable analog NC inputs
10
147
Default mask for analog NC inputs
10
148-163
Setting value from PLC for the analog NC inputs
10
166
Overwrite mask for analog NC outputs
10
167
Default mask for analog NC outputs
10
168
Disable analog NC outputs
10
170-185
Setting value from PLC for the analog NC outputs
Signals from NC to PLC
10
60, 186-189
Actual value of digital NC inputs
10
64, 190-193
Setpoint of digital NC outputs
10
194-209
Actual value of analog NC inputs
10
210-225
Setpoint of analog NC outputs