NC Commissioning with HMI Advanced
11.8 Loadable compile cycles
Manual
480
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
●
Interface version of a compile cycle that has not yet been loaded
HMI Advanced (excerpt):
Services
> <Medium> > "Properties" softkey
Display:
,QKDOWORDGDEOHFRPSLOHF\FOH
,QWHUIDFH#,QWHUIDFHV VWGLJLW!QGGLJLW!
●
Interface version of a loaded compile cycle
HMI Advanced:
Diagnosis > Service Display > Version > NCU Version
Display (excerpt)
&&,QWHUIDFH9HUVLRQ
#1&.23,
/RDGHG&RPSLOH&\FOHV
,GHQWLILHU!9HUVLRQ!'DWHJHQHUDWHG!
&&VWDUWDGGUHVV
B1B,GHQWLILHU!9HUVLRQ!,)VWGLJLW!QGGLJLW!B(/)
Example:
_N_CLC407IF003001_ELF corresponds to interface version: 3.1
dependencies
The following dependencies exist between the interface versions of a compile cycle and the
NC system software:
●
1. Digit of the interface version number
The 1st digit of the interface version number of a compile cycle and the NC system
software must be the same.
●
2. Digit of the interface version number
The 2nd digit of the interface version number of a compile cycle must be less than or
equal to the 2nd digit of the NC system software.
CAUTION
If alarm 7200 is displayed after the NC has booted, this means no compile cycle has
been loaded!