NC Commissioning with HMI Advanced
11.8 Loadable compile cycles
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
483
11.8.6
Data descriptions (MD)
General machine data
60900 + i
where i = 0. 1. 2. 3 ...
CC_ACTIVE_IN_CHAN_XXXX[n]
with: XXXX = function identifier, n = 0 or 1
MD number
n = 0: Activating the technology function in channels
n = 1: Additional functions within the technology function
Default setting: 0
Min. input limit: 0
Max. input limit: FFFF
Changes effective after RESET
Protection level: 2/7
unit: -
Data type: UINT16
Valid as of software version: 2.2
Meaning:
Activating the technology function in the channels:
The technology function is activated in the channels by means of index n = 0.
Bit 0 = 1: Technology function activated in Channel 1
Bit n = 1: Technology function activated in channel n+1
For more details about which channels a technological function can be activated, please
refer to the manuals below.
Additional functions within the technology function:
The MD with index n = 1 activates additional functions within the relevant technology
function. See References below.
References:
/FB3/ Function Manual - Special Functions TE1-TE8.