Drive Optimization with HMI Advanced
14.2 Measuring functions
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
509
Starting measuring functions
Measuring functions initiating a traversing movement are only selected using the specific
softkey. The actual start of the measuring function and thus of the traversing movement is
always carried out with NC START on the machine control panel.
If the main screen of the measuring function is quitted without the traversing motion being
initiated, the selection of the traversing function is canceled.
Once the traversing function has been started, the main screen can be exited without any
affect on the traversing movement.
Note
JOG mode must be selected when measuring functions are started.
Further safety notices
The user must ensure that when the measuring functions are used:
●
The EMERGENCY STOP button is always within the reach.
●
No obstacles are in the traversing range.
Canceling measuring functions
The following events will cancel active measuring functions:
●
Hardware limit switch reached
●
Traversing range limits exceeded
●
Emergency stop
●
Reset (mode group, channel)
●
NC STOP
●
No controller enabling command
●
Canceling drive enable
●
Canceling traversing enable
●
Selection of parking (in position-controlled operation).
●
Feed override = 0%
●
Spindle override = 50%
●
Change in operating mode (JOG) or operating mode JOG not selected
●
Actuation of traversing keys
●
Actuation of handwheel
●
Alarms leading to axis shutdown