Software installation/update and data backup
16
16.1
PTP network connection
The functions described in this section (software installation/update) require a network
connection to an external computer (PG/PC) which contains an enabled network access
directory.
If the SINUMERIK 840Di sl is not part of a larger network (WAN, LAN), a simple PTP (peer-
to-peer) connection via Ethernet and TCP/IP can be established for service applications.
16.1.1
Establishing a network connection
For the network link, the PCU 50.3 is connected with the external computer directly via a
crossed Ethernet cable (twisted pair crossed 10baseT/100baseTX Ethernet cable).
6,180(5,.'LVO
3&8
3*3&HJ3*
(WKHUQHWFDEOH
ರ7ZLVWHGSDLUFURVVHGEDVH7EDVH7;ರ
)XQFWLRQDOLW\RIWKH(WKHUQHWLQWHUIDFHV
XQGHU:LQGRZV;3
'+&3FOLHQW
'+&3VHUYHU
Figure 16-1 PTP link: PCU 50.3 - External computer (PG/PC)