06.03
2.13
ADI4 (analog drive interface for 4 axes) (SW 09.01 and higher)
2-115
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
S
Connecting cable: The required connecting cables must be provided by the
user.
–
Power supply voltage X6-1, pins 1 and 12 (P24EXT2):
Wire, conductor cross-section 1.5mm
2
(AWG16)
–
Digital outputs X6-1, pins 2–9:
Wire, conductor cross-section 0.5–1.5mm
2
(AWG20–AWG16)
–
NC Ready X6-2, pins 10 and 11:
Wire, conductor cross-section 1.5–3.5mm
2
(AWG16–AWG12)
Notice
The lengths of the digital signal lines must not exceed 30m.
2 Hardware Descriptions