06.03
5.4 Machine control panel (MCP)
5-141
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
The basic PLC program is part of the SINUMERIK 840Di installation.
The installation of the basic PLC program as a SIMATIC S7 library is described
in Subsection 8.2.2 (page 8-251) in detail.
SIMATIC Manager STEP7
SIMATIC Manager S7 is used for adapting the basic PLC and user programs
(e.g. call of FC 25).
The following manuals are required to start up an MCP:
/FB1/
Description of Functions, Basic Machine: P3, Basic PLC Program
Description of the program structure and modules of the basic PLC program.
/BH/
Operator Components, Manual
Description of MCP (interfaces, electrical connection, etc.)
/Z/
Catalog NC Z
Components required for connection: Cables, connectors, etc.
To start up the MCP, the automation system must be electrically and mechani-
cally connected completely with respect to NCK, PLC and MCP.
The drives must be secured against accidental moving.
5.4.2
Parameterization of the MCP
The MCP’s electrical connections and connections for MPI communication are
made using the interfaces on the rear side of the MCP.
1
MPI interface
Power supply interface
S3 DIP switch
X10
X20
S3
3
4
2
EMERGENCY
STOP button
connections
1 2 3 4
LEDs1...4
Connection for equipotential bonding conductor
1
2
3
SHIELD M24
P24
Fig. 5-4
Position of interfaces on rear panel of MCP
References
Automation
system
Electrical
connection
5 MPI Communication