06.03
10.2 Machine and setting data
10-277
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
Table 10-3
Protection levels
Protection
level
Type
User
Access to (examples)
0
Pass–
SIEMENS
All functions, programs and data
word
1
Pass–
Machine manufacturer:
Defined functions, programs and data;
word
Development
e.g.: Enter options
2
Pass–
Machine manufacturer:
Defined functions, programs and data;
word
System start-up engineer
e.g.: Majority of machine data
3
Pass–
Final user:
Assigned functions, programs and data;
word
Service
4
Key–
Final user:
Less than protection levels 0 to 3;
switch
Programmer
defined either by machine manufacturer or
pos. 3
setter
end user
5
Key–
Final user:
Less than protection levels 0 to 3;
switch
Qualified operator
defined by the end user
pos. 2
who will not program
6
Key–
Final user:
Example:
switch
Trained operator
Only program selection, input of tool wear
pos. 1
who will not program
and zero offsets
7
Key–
Final user:
Example:
switch
Semiskilled operator
No inputs, no program selection
pos. 0
only possible if the machine control panel can be
operated
Descending
access rights
For the four possible password levels with their access permissions, the pass-
words can be entered in the control area DIAGNOSIS by actuating the soft key
SET PASSWORD.
References:
/BA/
Operator’s Guide
Please note that a password remains valid until access authorization is reset
with the soft key DELETE PASSWORD.
Access rights are thus not automatically deleted by power ON!
Up to eight characters are possible for a password. When choosing the pass-
word, it is recommended to limit yourself to the character set of the operator
panel. If the character has less than 8 characters, the remaining characters are
interpreted as a blank.
Setting the
password
Resetting
the password
Possible
characters
10 NC Start-Up with HMI Advanced