10.4 Memory configuration
10-301
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
The following Windows NT system settings are required:
1. Startup / Shutdown
Windows NT start bar: Start > Settings > Control Panel > System > Tab:
Startup/Shutdown
General
Startup/Shutdown
Hardware Profiles
User Profiles
Performance
Environment
System Startup
Startup:
”SINUMERIK” /NoSerialMice
Show list for:
3
Recovery
When a STOP error occurs, do the following:
Write an event to the system log
Send an administrative alert
D:\Memory.dmp.
OK
Cancel
Automatically reboot
System Properties
Write debugging information to:
Overwrite any existing file
Fig. 10-4 Dialog: Windows NT system settings
The following settings must be made:
–
Option: “Write debugging information to:” selected
–
Drive and file specified.
The file should preferably reside on drive D: to prevent it being stored in
a ghost image, and the file name must be valid according to Windows
NT file name conventions.
–
Option: “Overwrite any existing file” selected
If settings are incorrect, the following message box appears:
OK
SINUMERIK 840Di NCK/PLC
Alarm: Wrong Windows ”System Properties” settings for Recovery.
Windows NT
system settings
10 NC Start-Up with HMI Advanced