06.03
11.1 Alarm and message texts
11-406
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
11.1.4
Syntax for alarm text files
The following alarm numbers are available for alarms relating to cycles, compile
cycles and the PLC:
Table 11-2
Alarm numbers for cycle, compile cycle and PLC alarms
Number range
Designation
Effect
Delete
60000–60999
Cycle alarms
(Si
)
Display, NC start disable
Reset
61000–61999
y
(Siemens)
Display, NC start disable,
axis/spindle standstill
Reset
62000–62999
Display
Cancel
63000–64999
Reserved
65000–65999
Cycle alarms
(
)
Display, NC start disable
Reset
66000–66999
y
(user)
Display, NC start disable,
axis/spindle standstill
Reset
67000–67999
Display
Cancel
68000–69000
Reserved
70000–79999
Compile cycle alarms
400000–499999
PLC alarms, general
500000–599999
PLC alarms for channel
600000–699999
PLC alarms for axis and
spindle
700000–799999
PLC alarms for user
800000–899999
PLC alarms for sequential
controllers/graphs
The text file for cycle and compile cycle alarms has the following structure:
Table 11-3
Structure of text file for cycle alarm texts
Alarm number
Display
Help ID
Text or alarm number
60100
1
0
“No D number %1 programmed”
60101
1
0
60100
...
...
...
...
65202
0
1
“Axis %2 in channel %1 is still moving”
// Alarm text file for cycles in German
References:
/FB/,
Description of Functions, Basic Machine
P3
Basic PLC Program
Section: Lists
Alarm number list
This number defines the alarm display type:
0: Display in alarm line
1: Display in a dialog box
Alarm numbers
Format of the
text file for
cycle alarm texts
Alarm number
Display