06.03
12.3 Dry run of spindle
12-415
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
12.3
Dry run of spindle
Check enabling signals on drive
I/RF module
63 pulse enable
64 drive enable
48 DC link start
Drive module
663 pulse enable
Check interface signals (DB31–48)
DBB0
Spindle speed override
DBX1.7
Compensation active
DBX1.5/DBX1.6
Position measuring system 1/2
DBX1.3
Axis/spindle disable
DBX2.1
Controller enable
DBX16.7
Delete S value
DBX3.6
Velocity/spindle speed limi-
tation and MD 35160
DBX4.3
Feed stop/spindle stop
DBX20.1
HLGSS
DBX2.2
Spindle reset when MD 35050=1
DBX21.7
Pulse enable
Check machine and setting data
MD32250
Nominal output voltage
1)
MD32260
Nominal output speed
MD 35100–35150
Spindle speed limitation
MD 36200
AX_VELO_LIMIT
SD 41200
JOG_SPIND_SET_VELO
SD 43220
SPIND_MAX_VELO_G26
SD 43210
SPIND_MIN_VELO_G25
Service display
Enable spindle
(controller enable NC,
enable on drive)
Does the
spindle ro-
tate?
Is
rotational
direction
OK
yes
no
no
Define speed
Specified speed 100rpm
Actual
speed
=
Set
speed?
no
yes
yes
1
1) Speed setpoint matching
– ADI4: –> MD32250
0
0
– SIMODRIVE 611 universal / E; POSMO CD/CA, SI
–> MD32250 = 0
Check:
MD32100: AX_MOTION_DIR
Check:
MD31000–31080: (encoder matching)
12 Dry Run of Axis and Spindle