7.3 SIMATIC S7 project
7-233
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
After this dialog has been confirmed using the button: “OK”, the dialog: “DP
Slave properties” opened.
Depending on the drive functionality to be used, you must select the correct
message frame type from the listbox: default. The selected message frame type
only defines the number of cyclically transferred process data units within the
cyclic message frames.
The number of cyclically transferred process data units depends on:
–
The number of axes per drive module
–
The number of encoders used per axis
–
The drive functionality used.
The following message frame types are predefined for parameterization of the
DP slave 611U:
Table 7-1
Message frame types
Message frame type
Description
1 axis,
Message frame type 102,
PDA 6/10
nset interface with encoder 1
2 axes,
Message frame type 102,
PDA 6/10
nset interface with encoder 1
1 axis,
Message frame type 103/104,
PDA 7/15
nset interface with encoders 1 and 2 (103)
or encoders 1 and 3 (104)
2 axes,
Massage frame type 104,
PDA 7/15
nset interface with encoders 1 and 3
1 axis,
Message frame type 105,
PDA 10/10
nset interface with DSC and encoder
2 axes,
Message frame type 105,
PDA 10/10
nset interface with DSC and encoders 1
and 2
1 axis,
Message frame type 106/107,
PDA 7/15
nset interface with DSC and encoders 1
and 2 (106) or encoders 1 and 3 (107)
2 axes,
Message frame type 106/107,
PDA 7/15
nset interface with DSC and encoders 1
and 2 (106) or encoders 1 and 3 (107)
PDA x/y number of process data words, x: setpoints, y: actual values
DSC
Functionality “Dynamic Servo Control”
SIMODRIVE 611 universal E
Encoder 3
Encoder 1
Encoder 1
Encoder 2
Encoder 2
SIMODRIVE 611 universal
Dialog: DP Slave Properties
Tab: Configuration
Default: <Message Frame Type>
OK
Message frame
type
Dialog