Number
Ref.
Name
Identifier
9235
USER_BEGIN_WRITE_RPA_2
Start of the second RPA area
9236
USER_END_WRITE_RPA_2
End of the second RPA area
9237
USER_CLASS_WRITE_RPA_3
Protection level for the third RPA area
9238
USER_BEGIN_WRITE_RPA_3
Start of the third RPA area
9239
USER_END_WRITE_RPA_3
End of the third RPA area
9240
USER_CLASS_WRITE_TOA_NAME
Change tool name and duplo
9241
USER_CLASS_WRITE_TOA_TYPE
Change tool type
9247
USER_CLASS_BASE_ZERO_OFF_PA
IAM, IM1 availability of the basic offset in the Pa-
rameter operating area
9248
USER_CLASS_BASE_ZERO_OFF_MA
IAM, IM1 availability of the basic offset in the Ma-
chine operating area
References:
/FB/
Description of Functions – Basic Machine:
A2, Various Interface Signals
Section: MMC machine data for protection levels
Single data
The protection level of individual machine and/or setting data can be modified in
the file SGUD.DEF.
Example:
The axial machine data item CTRLOUT_SEGMENT_NR requires protection
level 3 for reading and protection level 2 for writing.
Syntax:
REDEF $machine data string APR n APW m
APR n: Defining the protection level for reading (Read) the data
APW m: Defining the protection level for writing (Write) the data
File SGUD.DEF:
%_N_UGUD_DEF
;$PATH=/_N_DEF_DIR
REDEF $MA_CTRLOUT_SEGMENT_NR APR 3 APW 2
M30
References:
/PGA/ Programming Guide Advanced
Section: File and Program Management
Defining protection levels for user data (GUD)
10.2.3
Machine data display filter
Through the use of the machine data display filter, it is possible to reduce the
number of displayed machine data of a certain area, e.g. general machine data
or channel machine data, for special purposes.
Display filters are provided for the following machine data areas:
S
General machine data
Machine data
areas
10 NC Start-Up with HMI Advanced