06.03
10.3 System data
10-282
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
Computational resolution:
1,000 increments/mm
Programmed path:
97.3786mm
Effective value =
97.379mm
To keep the executed rounding more traceable, it is reasonable to use powers
to the 10th for the computational resolution (100, 1000, 10.000).
In MD 9004: DISPLAY_RESOLUTION, you can set the number of decimal
places after the decimal point for the position values on the operator panel.
The limitation of the input limits depends on the display and input possibilities on
the operator panel.
This limit is reached at 10 digit positions plus decimal point plus sign.
Examples of programming in the
1
/
10
m
m-range:
Supposed all linear axes of a machine will be programmed and traversed within
the range of values 0.1 ... 1,000
m
m.
To position exactly to 0.1
m
m, the computational resolution must be set to
10
4
incr. /mm.
Check MD 10200: INT_INCR_PER_MM = 10,000 [incr. /mm]:
Example of related parts program:
N20 G0 X 1.0000 Y 1.0000 ;
Axes move to position
X=1.0000mm, Y=1.0000mm;
N25 G0 X 5.0002 Y 2.0003 ;
Axes move to position
X=5.0002mm, Y=2.0003mm
Table 10-5
Resolutions: Machine data
Number
Identifier
Name/remarks
Ref.
General ($MN_ ...)
9004
DISPLAY_RESOLUTION
Display resolution
G2
9011
DISPLAY_RESOLUTION_INCH
Display resolution for INCH unit system
G2
10200
INT_INCR_PER_MM
Computational resolution for linear positions
G2
10210
INT_INCR_PER_DEG
Computational resolution for angular positions
G2
/FB/
Description of Functions – Basic Machine
G2 Velocities, Traversing Ranges, Accuracies,
Section: Input/display resolution, calculation resolution
Tip
Display resolution
Limit values for
input and
display
Machine data
References
10 NC Start-Up with HMI Advanced