10.6 Digital and analog I/O devices
10-379
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
10.6
Digital and analog I/O devices
The following digital and analog signal modules are available:
Digital I/O modules
–
MCI board extension module (option)
On the MCI board extension module (option) there are 4 digital inputs/
outputs (Section 2.4, page 2-62).
–
PP 72/48
The I/O module PP 72/48 has 72 digital inputs and 48 digital outputs
(Section 2.12, page 2-93).
–
ADI4
The ADI4 has two digital input and output bytes that are used for
ADI4-internal functions and as I/O signals at the interfaces of the module
(Section 2.13, page 2-105).
–
SIMATIC S7: ET200 modules
Via the PROFIBUS DP it is possible to connect all subtypes of SIMATIC-
S7 I/O modules of type ET200 (e.g. ET200M) as long as they support a
data transmission rate of 12 Mbaud.
Analog I/O modules
–
SIMATIC S7: ET200 modules
See above.
Notice
The digital and analog input/outputs connected on PROFIBUS DP are provided
for both NC and PLC.
It is the sole responsibility of the user to avoid access conflicts:
On the side of the NC: Parts program/synchronized action
On the side of the PLC: PLC user program.
/FB/
Description of Functions, Extended Functions,
A4 Digital and Analog NCK I/Os
10.6.1
Setting parameters for the number of inputs/outputs in use
The maximum number of digital or analog input/outputs that can be used for the
NC is:
Total
MCI board
extension
PROFIBUS
modules
Analog inputs
8
–
8
Analog outputs
8
–
8
Digital inputs
36
4
32
Digital outputs
36
4
32
References
Max. number
10 NC Start-Up with HMI Advanced