06.03
13.6 Trace function
13-438
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
–
Individual bits: xxxx xxxx
–
1: selected
–
0: not selected.
By default, all bits are selected.
The input field “Threshold” is only used to enter the triggering threshold for the
physical address of trace 1. If you exit the input screen form with the Ok soft
key, this hex value is then entered in the field “Threshold” of the main screen
of the trace function.
13.6.4
Measuring
After parameterization has been completed, you then enable measurement by
pressing soft key Start.
The measurement is carried out once the set trigger condition of trace 1 is ful-
filled.
The measurement is completed after the set measurement duration is expired.
With the end of the measurement, the graphics are prepared automatically. Use
the “Display” soft key to call the display functions of the graphics (see next Sec-
tion).
With the Stop soft key, you can cancel a running measurement at any time. A
canceled measurement cannot be displayed.
Input field:
Threshold
Soft key:
Start
End of
measurement
Soft key:
Stop
13 Drive Optimization using HMI Advanced