Table 7-5
Assignment of PROFINET interface X160 in the 10/100 MBit/s mode
Connector
Pin
Name
Type
Remark
/('
/('
1
DA+
B
Bidirectional pair A+
2
DA-
Bidirectional pair A-
3
DB+
Bidirectional pair B+
4
DC+
Bidirectional pair C+
5
DC-
Bidirectional pair C-
6
DB-
Bidirectional pair B-
7
DD+
Bidirectional pair D+
8
DD-
Bidirectional pair D-
Shield
-
-
On connector housing
-
LED green
(Link)
-
Lights up orange: 1000 Mbit/s
Off: No or faulty connection
-
LED orange
(Activity)
-
Flashes: Data exchange
Off: No data exchange
B = Bidirectional
Note
The PROFINET interface has what is known as autocrossing functionality, i.e. when required,
transmit and receive lines are switched over. Thus, no crossover cables are necessary.
Cable specification
For PROFINET, you always require a data transmission rate of 100 Mbit/s (Fast Ethernet) in full
duplex mode. For data transfer purposes, you can use twisted-pair copper cables (4-wire,
100Base-T).
Table 7-6
Cable specification for X150 ports 1, 2
Characteristic
Version
Connector type
RJ45 socket
Cable type
Industrial Ethernet cable (as of CAT5)
Max. cable length
100 m
Interface description
7.3 Ethernet
PPU 1740
70
Equipment Manual, 01/2019, A5E47615272B AA
Summary of Contents for SINUMERIK ONE PPU 1740 Series
Page 22: ...System overview 2 2 System configuration PPU 1740 22 Equipment Manual 01 2019 A5E47615272B AA ...
Page 82: ...Interface description 7 7 USB PPU 1740 82 Equipment Manual 01 2019 A5E47615272B AA ...
Page 92: ...Connectable components 8 1 NX10 3 NX15 3 PPU 1740 92 Equipment Manual 01 2019 A5E47615272B AA ...
Page 100: ...Spare parts and accessories PPU 1740 100 Equipment Manual 01 2019 A5E47615272B AA ...