SIPLUS HCS4200 PROFINET/PROFIBUS DP
Operating Instructions, 07/2019, A5E35066204A/006
131
Functions
9
9.1
Overview of functions
The table below shows which functions are available for the different POM versions.
Function
POM4220
Lowend,
Flexible
POM4220
Midrange
phase angle
control
POM4220
Highend
POM4320
Half-wave control
x
x
x
x
Phase angle control
-
x
x
x
Defined soft start
(fixed number of half-waves)
-
x
x
x
3
Adaptive soft start
-
-
x
-
Explicit switch-on of heating
x
x
x
x
Time-delayed startup of the channels
x
x
x
x
Soft start during heater operation
-
-
x
-
Channel control over setpoints
x
x
x
x
Channel control over fields
x
x
x
x
Line voltage compensation
x
1
x
1
x
x
Power control
-
-
x
-
Parameter assignment of behavior of
the power outputs
x
x
x
x
Phase control monitoring
x
x
x
x
Rotating-field test
-
-
x
2
x
Line voltage monitoring
x
1
x
1
x
x
Frequency monitoring
x
x
x
x
Temperature monitoring
x
x
x
x
Monitoring power channels
x
x
x
x
Monitoring power channels with loads
connected in parallel
-
-
x
-
Total current monitoring
-
-
x
-
Fault current monitoring
-
-
x
-
1
With PM-U/I
2
Only with connection type economy circuit
3
POM4320 as of MLFB -0AA2 is designed for phase angle control
Summary of Contents for SIPLUS HCS Series
Page 1: ...SIPLUS HCS4200 PROFINET PROFIBUS DP ...