Communications
10.2 Acyclic data exchange
SIPLUS HCS4200 PROFINET/PROFIBUS DP
Operating Instructions, 07/2019, A5E35066204A/006
171
Data record 200 "Measured values" (HCS4200 combined mode and HCS4200 with
POM4220 Highend)
The data set describes an HCS function and addresses the HCS.
Byte
Description
Data POM 1
0
Internal temperature
1
Reserved
2, 3
Frequency (to one decimal place)
4, 5
Voltage measured value
1
L12/LX1 (with one decimal place)
6, 7
Voltage measured value
1
L23/LX3 (with one decimal place)
8, 9
Voltage measured value
1
L31/unused (with one decimal place)
Data POM 2
…
…
…
…
...
Data POM 24 …
...
1)
Voltage measured value only for POM4320 and POM4220 Highend, otherwise value = 0
Definition is via an array [1 … 24] with one element of type "Structure". This consists of two
elements of the Byte type and four elements of Word type .
The POM number corresponds to the array index.
The length of the data record corresponds to the number of POMs used.
Data record 201 "Versions"
The data set describes an HCS function and addresses the HCS.
Byte
Description
CIM / PM
0 … 3
FW version of CIM fieldbus controller
4 … 7
FW version of CIM HCS master
8
HW version of CIM
9
HW version of PM
10 … 3 FW version of PM
POM 1
14 … 17 Firmware version POM 1
18
POM4220: HW version POM 1
POM4320: Hardware version triac POM 1
19
POM4220: 0
POM4320: HW version fuse POM 1
POM 2
…
…
…
…
…
POM 12/24
…
…
All firmware versions contain one element of type "Char" and three elements of type "Byte".
The hardware versions are all of type "Byte".
PROFINET: Definition of the POM versions is via an array [1…24] with one element of type
"Structure".