Technical specifications
13.4 Technical specifications of POM
SIPLUS HCS4200 PROFINET/PROFIBUS DP
Operating Instructions, 07/2019, A5E35066204A/006
221
Article number
6BK1942-2DA00-0AA0
6BK1942-2FA00-0AA0
Setpoint input
Percent
Yes
Watts
Yes
No
Heating power
•
Number of digital outputs
8
12
•
Number of heating elements per
output, max.
5; Recommended, de-
pends on tolerance of heat-
ing elements
1
•
Output voltage for heating power
230 V
•
2nd output voltage for heating pow-
er
277 V
•
3rd output voltage for heating power 400 V
110 V
•
4th output voltage for heating power 480 V
70 V
•
5th output voltage for heating power
45 V
•
Power carrying capacity per output,
min.
400 W; At 230 V AC
100 W; At 230 V AC
•
Power carrying capacity per output,
max.
4 600 W; At 230 V AC
3 680 W; At 230 V AC
–
for heating elements with high
inrush current, max.
2 700 W; At 230 V AC
1 600 W; At 230 V AC
•
Output current for heating power
20 A; max.
16 A; max.
•
Melting I2t value
120 A²·s
20 A²·s
•
Design of short-circuit protection
per output
Melting fuse 25 A
Fuse 16 A
•
Design of overvoltage protection
Transil Diode
Connection method
•
Design of electrical connection at
output for heating and fan
Plug, 4-pole, with spring-
loaded connection
Connector, 6-pole with
spring-loaded connection
–
Connectable conductor cross-
sections, solid
1x (0.2 ... 10 mm²)
–
Connectable conductor cross-
sections, finely stranded with
wire end processing
1x (0.25 ... 6 mm²)
–
Connectable conductor cross-
sections for AWG cables,
stranded
1x (24 ... 8)
Summary of Contents for SIPLUS HCS Series
Page 1: ...SIPLUS HCS4200 PROFINET PROFIBUS DP ...