Technical specifications
13.4 Technical specifications of POM
SIPLUS HCS4200 PROFINET/PROFIBUS DP
226
Operating Instructions, 07/2019, A5E35066204A/006
Article number
6BK1943-2AA00-0AA2
6BK1943-2BA00-0AA2
Power electronics
Type of load
Ohmic load
Type of control of the heating elements Half-wave control, phase control and soft start
Power capacity, max.
57.6 kW; At 400 V AC
64.8 kW; At 480 V AC
•
For phase against phase with fan at
40 °C, max.
57.6 kW; At 400 V AC
64.8 kW; At 480 V AC
Switching capacity current per phase,
max.
83 A
80 A
Short-time withstand current (SCCR)
acc. to UL 508A
100 kA
Load connection type
Star connection with neutral conductor
(single-phase)
No
Open delta connection (single-phase)
Yes; Incoming fuse contained in the device
Closed delta connection (3-phase)
No
Star connection with neutral conductor
(2-phase)
No
2-pole switching
No
Setpoint input
Percent
Yes
Watts
No
Heating power
•
Number of digital outputs
9
•
Number of heating elements per
output, max.
1
•
Output voltage for heating power
400 V
•
2nd output voltage for heating pow-
er
480 V
•
Power carrying capacity per output,
min.
200 W; At 400 V AC
200 W; At 480 V AC
•
Power carrying capacity per output,
max.
6 400 W; At 400 V AC
7 200 W; At 480 V AC
–
for heating elements with high
inrush current, max.
4 000 W; At 400 V AC
4 000 W; At 480 V AC
•
Output current for heating power
16 A; max.
15 A; max.
•
Melting I2t value
250 A²·s
400 A²·s
•
Design of short-circuit protection
per output
Fuse 16 A
Melting fuse 20 A
•
Design of overvoltage protection
Transil Diode