Ann.LSA
VDEW/ZVEI
FNo. Meaning
OpFtNo.CAGIBTTypInf
¨©©©©ª©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©ª©©ª©©ª©©©ª©©ª©©ª©©ª©©©ª©©©
2145Emerg. O/C protection: Trip 3pole
C 241 61145
2704>AR: Reset auto-reclose function
CG
GI 40 4
2709>AR: Block delayed auto-reclose
CG 76 GI 40 9
2711>AR: External start for internal AR
CG 28 GI 40 11
2712>AR: Ext. Trip L1 for internal AR
CG 29 GI 40 12
2713>AR: Ext. Trip L2 for internal AR
CG 30 GI 40 13
2714>AR: Ext. Trip L3 for internal AR
CG 31 GI 40 14
2781AR: Auto-reclose is switched off
CG 79 GI 40 81
2782AR: Auto-reclose is switched on
CG
CAGI p 16
2783AR: Auto-reclose is blocked
CG 72 GI 40 83
2784AR: Auto-reclose is not ready
CG
CAGIBT p130
2785AR: Auto-reclose is dynamically blockedCG 233 GI 40 85
2787AR: Circuit breaker not ready
CG 78 GI 40 87
2801AR: Auto-reclose in progress
CGCG228 GI 40101
2813AR: 1pole dead time for RAR is running CGCG230 GI 40113
2814AR: 3pole dead time for RAR is running CGCG230 GI 40114
2833AR: 3pole dead time 1 for DAR running CGCG230 GI 40133
2834AR: 3pole dead time 2 for DAR running CGCG230 GI 40134
2835AR: 3pole dead time 3 for DAR running CGCG230 GI 40135
2851AR: Close command from auto-reclose
C 248CA BT p128
2854AR: Close command after 3pole DAR cycleC
CA p129
2863AR: Definitive trip
C 74 40163
2871AR: Trip during 1pole AR cycle
C
40171
2931Synchro-check function is switched off CG
GI 41 31
2932Synchro-check function is blocked
CG
GI 41 32
2934Synchro-check function faulty
CG
GI 41 34
2935Synchro-check supervision time expired C
41 35
2941Synchro-check function is running
CG
GI 41 41
2942Synchro-check function override/bypass C
41 42
2943Synchronism (U1>,U2>) detected
C
41 43
2944Live line,dead busbar(U1>,U2<) detectedC
41 44
2945Dead line,live busbar(U1<,U2>) detectedC
41 45
2946Dead line,dead busbar(U1<,U2<) detectedC
41 46
2947Sync.: Voltage diff. greater than limitC
41 47
2948Sync.: Freq. diff. greater than limit C
41 48
2949Sync.: Angle diff. greater than limit C
41 49
2951Synchronism release (to ext. AR)
C
41 51
2961Close command from synchro-check
C
41 61
3651Distance protection is switched off
CG 55 GI 28 51
3652Distance protection is blocked
CG 48 GI 28 52
3653Distance protection is active
CG
GI 28 53
3671Dist.: General fault detection
CG144 28 71
3672Dist.: Fault detection , phase L1
CG145 GIBT 28 72
3673Dist.: Fault detection , phase L2
CG146 GIBT 28 73
3674Dist.: Fault detection , phase L3
CG147 GIBT 28 74
3675Dist.: Fault detection , earth fault
CG148 GIBT 28 75
3681Dist.: Fault detection only phase L1
C 161 28 81
3682Dist.: Fault detection phase L1,E
C 162 28 82
3683Dist.: Fault detection only phase L2
C 163 28 83
3684Dist.: Fault detection phase L2,E
C 164 28 84
3685Dist.: Fault detection phase L1,2
C 165 28 85
3686Dist.: Fault detection phase L1,2,E
C 166 28 86
3687Dist.: Fault detection only phase L3
C 167 28 87
3688Dist.: Fault detection phase L3,E
C 168 28 88
3689Dist.: Fault detection phase L1,3
C 169 28 89
3690Dist.: Fault detection phase L1,3,E
C 170 28 90
3691Dist.: Fault detection phase L2,3
C 171 28 91