FNo.Abbreviation Meaning
OpFtEIOT
¨©©©©ª©©©©©©©©©©©©©ª©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©©ª©©ª©©ª©ª©©©
1278E/F undefinedEarth fault (isol./comp.) undef. dir. E OT
1281E/F Det. TripTrip by earth fault det. (isol./comp.) C E OT
1289Iea
Active component Iea
E
1290Ier
Reactive component Ier
E
1303>E/F block
>Block E/F protection
IOT
1311>E/F comp. on>Switch on directional E/F comparison IOT
1312>E/F comp.off>Switch off directional E/F comparison IOT
1316>E/F Recept >Carrier reception for direct. E/F compC C IOT
1317>E/F Rec.Fail>Carrier reception for dir. E/F faulty CG IOT
1331E/F Prot. offEarth fault protection is switched off CG OT
1332E/F blocked Earth fault protection is blocked
CGCG OT
1333E/F active
Earth fault protection is active
OT
1334E/F Dir.blockEarth fault prot. direct.stage blocked OT
1341E/F Flt75%Ie>Earth fault detection 75% Ie picked up CG OT
1342E/F Flt Ie<->Earth fault detection non-direct. Ie
C OT
1343E/F Flt Ie ->Earth fault detection directional Ie
C OT
1344E/F Ue>
Earth fault displacement voltage Ue>
OT
1351E/F T-Delay Earth fault protection time expired
OT
1352E/F T->
Earth fault prot. dir. time expired
OT
1353E/F T<->
Earth fault prot. non-dir. time expired OT
1361E/F Trip
Trip by earth fault protection
C OT
1381E/F Dir off Earth fault dir. comp. is switched off CG OT
1384E/F Send
Carrier transmission for dir. comp. E/F C OT
1385E/F Echo
Echo signal for directional comp. E/F C OT
1386E/F TransBlocTransient block. of E/F protection
C OT
1501>O/L on
>Switch on thermal overload protection IOT
1502>O/L off
>Switch off thermal overload protection IOT
1503>O/L block
>Block thermal overload protection
IOT
1511O/L Prot. offThermal overload prot. is switched off CG OT
1512O/L blocked Thermal overload protection is blocked CG OT
1513O/L active
Thermal overload protection is active OT
1515O/L Warn I
Thermal overload prot.: Current warningCG OT
1516O/L Warn Î
Thermal overload prot.: Thermal warningCG OT
1517O/L pickup Î Thermal overload prot.: Pick-up thermalCG OT
1521O/L Trip
Thermal overload protection trip
C OT
2003>Emer. block >Block emergency overcurrent protection IOT
2010>I>> block
>Block I>> stage of emerg. O/C protec. CG IOT
2051Emer. off
Emergency O/C protect. is switched off CG OT
2052Emer. block Emergency O/C protection is blocked
CG OT
2053Emer. active Emergency O/C protection is active
OT
2054Emer. mode
Emergency O/C protection is running
CG OT
2061Emer.Gen.Flt Emerg. O/C prot.: General fault detect. OT
2062Emer. Flt L1 Emerg. O/C prot.: Fault detection L1
OT
2063Emer. Flt L2 Emerg. O/C prot.: Fault detection L2
OT
2064Emer. Flt L3 Emerg. O/C prot.: Fault detection L3
OT
2065Emer. Flt E Emerg. O/C prot.: Earth fault detection OT
2071Emer. Flt E Emerg. O/C earth fault detection only C
2072Emer. Flt L1 Emerg. O/C fault detection L1 only
C
2073Emer. Flt L1EEmerg. O/C fault detection L1E
C
2074Emer. Flt L2 Emerg. O/C fault detection L2 only
C
2075Emer. Flt L2EEmerg. O/C fault detection L2E
C
2076Emer. Flt L12Emerg. O/C fault detection L12
C
2077Emer.Flt L12EEmerg. O/C fault detection L12E
C
2078Emer. Flt L3 Emerg. O/C fault detection L3 only
C
2079Emer. Flt L3EEmerg. O/C fault detection L3E
C
2080Emer. Flt L13Emerg. O/C fault detection L13
C
2081Emer.Flt L13EEmerg. O/C fault detection L13E
C
2082Emer. Flt L23Emerg. O/C fault detection L23