Appendix
B-29
7SA6 Manual
C53000-G1176-C156-2
1115
Flt Locator: primary REACTANCE (Xpri =) Fault Locator
OUT
ON
OFF
128 73
4
1117
Flt Locator: secondary RESISTANCE
(Rsec =)
Fault Locator
OUT
ON
OFF
151 17
4
1118
Flt Locator: secondary REACTANCE
(Xsec =)
Fault Locator
OUT
ON
OFF
151 18
4
1119
Flt Locator: Distance to fault (dist =)
Fault Locator
OUT
ON
OFF
151 19
4
1120
Flt Locator: Distance [%] to fault (d[%] =)
Fault Locator
OUT
ON
OFF
151 20
4
1122
Flt Locator: Distance to fault (dist =)
Fault Locator
OUT
ON
OFF
151 22
4
1123
Fault Locator Loop L1E (FL Loop L1E)
Fault Locator
OUT_Ev
ON
1124
Fault Locator Loop L2E (FL Loop L2E)
Fault Locator
OUT_Ev
ON
1125
Fault Locator Loop L3E (FL Loop L3E)
Fault Locator
OUT_Ev
ON
1126
Fault Locator Loop L1L2 (FL Loop L1L2)
Fault Locator
OUT_Ev
ON
1127
Fault Locator Loop L2L3 (FL Loop L2L3)
Fault Locator
OUT_Ev
ON
1128
Fault Locator Loop L3L1 (FL Loop L3L1)
Fault Locator
OUT_Ev
ON
1132
Fault location invalid (Flt.Loc.invalid)
Fault Locator
OUT
*
ON
LED
BO
1133
Fault locator setting error K0,angle(K0)
(Flt.Loc.ErrorK0)
Fault Locator
OUT
*
ON
LED
BO
1143
BCD Fault location [1%] (BCD d[1%])
Fault Locator
OUT
*
*
LED
BO
1144
BCD Fault location [2%] (BCD d[2%])
Fault Locator
OUT
*
*
LED
BO
1145
BCD Fault location [4%] (BCD d[4%])
Fault Locator
OUT
*
*
LED
BO
1146
BCD Fault location [8%] (BCD d[8%])
Fault Locator
OUT
*
*
LED
BO
1147
BCD Fault location [10%] (BCD d[10%])
Fault Locator
OUT
*
*
LED
BO
1148
BCD Fault location [20%] (BCD d[20%])
Fault Locator
OUT
*
*
LED
BO
1149
BCD Fault location [40%] (BCD d[40%])
Fault Locator
OUT
*
*
LED
BO
1150
BCD Fault location [80%] (BCD d[80%])
Fault Locator
OUT
*
*
LED
BO
1151
BCD Fault location [100%] (BCD d[100%]) Fault Locator
OUT
*
*
LED
BO
1152
BCD Fault location valid (BCD dist.
VALID)
Fault Locator
OUT
*
*
LED
BO
1219
Active 3I0sen (sensitive Ie) = (3I0senA=)
Sensitive Earth
Flt.(comp/ isol.
starp.)
OUT
*
*
ON
OFF
1220
Reactive 3I0sen (sensitive Ie) =
(3I0senR=)
Sensitive Earth
Flt.(comp/ isol.
starp.)
OUT
*
*
ON
OFF
1251
>Switch on sensitive E/F detection
(>SensEF on)
Sensitive Earth
Flt.(comp/ isol.
starp.)
SP
*
*
LED BI
BO
1252
>Switch off sensitive E/F detection
(>SensEF off)
Sensitive Earth
Flt.(comp/ isol.
starp.)
SP
*
*
LED BI
BO
F.No.
Description
Function
Type of
Informa-
tion
Log-Buffers
Configurable in Matrix
IEC 60870-5-103
E
v
en
t
L
o
g
On
/O
ff
T
rip
(F
au
lt)
L
o
g
On
/Of
f
G
roun
d
F
a
u
lt
Lo
g
O
n
/O
ff
M
a
rk
e
d
in
Osc
ill.
Reco
rd
LED
B
ina
ry
In
pu
t
Fun
ct
io
n
K
e
y
B
ina
ry
O
u
tp
ut
C
h
at
te
r
B
lo
c
k
in
g
Ty
pe
In
fo
rm
a
tio
n
-N
o
D
a
ta
Un
it
(A
SDU)
G
e
ne
ra
l
In
te
rr
oga
ti
o
n
Summary of Contents for siprotec 7SA6
Page 2: ...Siemens Aktiengesellschaft Book No C53000 G1176 C156 2 ...
Page 18: ...xviii 7SA6 Manual C53000 G1176 C156 2 ...
Page 32: ...Introduction 1 14 7SA6 Manual C53000 G1176 C156 2 ...
Page 82: ...Hardware and Connections 2 50 7SA6 Manual C53000 G1176 C156 2 ...
Page 119: ...SIPROTEC 4 Devices 4 25 7SA6 Manual C53000 G1176 C156 2 Figure 4 20 CFC Logic example ...
Page 190: ...Configuration 5 62 7SA6 Manual C53000 G1176 C156 2 ...
Page 652: ...Installation and Commissioning 8 78 7SA6 Manual C53000 G1176 C156 2 ...
Page 724: ...Technical Data 10 56 7SA6 Manual C53000 G1176 C156 ...
Page 800: ...Appendix A 76 7SA6 Manual C53000 G1176 C156 2 ...
Page 866: ...Appendix B 66 7SA6 Manual C53000 G1176 C156 2 ...