A.13 List of Information
567
7UM62 Manual
C53000-G1176-C149-3
05504 >BLOCK df1/dt stage (>df1/dt block)
Rate-of-frequency-
change protection
SP
ON
OF
F
*
LED BI
BO
72
1
1
GI
05505 >BLOCK df2/dt stage (>df2/dt block)
Rate-of-frequency-
change protection
SP
ON
OF
F
*
LED BI
BO
72
2
1
GI
05506 >BLOCK df3/dt stage (>df3/dt block)
Rate-of-frequency-
change protection
SP
ON
OF
F
*
LED BI
BO
72
3
1
GI
05507 >BLOCK df4/dt stage (>df4/dt block)
Rate-of-frequency-
change protection
SP
ON
OF
F
*
LED BI
BO
72
4
1
GI
05511 df/dt is switched OFF (df/dt OFF)
Rate-of-frequency-
change protection
OUT
ON
OF
F
*
LED
BO
72
5
1
GI
05512 df/dt is BLOCKED (df/dt BLOCKED)
Rate-of-frequency-
change protection
OUT
ON
OF
F
ON
OFF
LED
BO
72
6
1
GI
05513 df/dt is ACTIVE (df/dt ACTIVE)
Rate-of-frequency-
change protection
OUT
ON
OF
F
*
LED
BO
72
7
1
GI
05514 df/dt is blocked by undervoltage (df/dt
U< block)
Rate-of-frequency-
change protection
OUT
ON
OF
F
ON
OFF
LED
BO
72
8
1
GI
05516 Stage df1/dt picked up (df1/dt pickup)
Rate-of-frequency-
change protection
OUT
*
ON
OFF
LED
BO
72
9
2
GI
05517 Stage df2/dt picked up (df2/dt pickup)
Rate-of-frequency-
change protection
OUT
*
ON
OFF
LED
BO
72
10
2
GI
05518 Stage df3/dt picked up (df3/dt pickup)
Rate-of-frequency-
change protection
OUT
*
ON
OFF
LED
BO
72
11
2
GI
05519 Stage df4/dt picked up (df4/dt pickup)
Rate-of-frequency-
change protection
OUT
*
ON
OFF
LED
BO
72
12
2
GI
05520 Stage df1/dt TRIP (df1/dt TRIP)
Rate-of-frequency-
change protection
OUT
*
ON
LED
BO
72
13
2
GI
05521 Stage df2/dt TRIP (df2/dt TRIP)
Rate-of-frequency-
change protection
OUT
*
ON
LED
BO
72
14
2
GI
05522 Stage df3/dt TRIP (df3/dt TRIP)
Rate-of-frequency-
change protection
OUT
*
ON
LED
BO
72
15
2
GI
05523 Stage df4/dt TRIP (df4/dt TRIP)
Rate-of-frequency-
change protection
OUT
*
ON
LED
BO
72
16
2
GI
05533 >BLOCK inadvertent energ. prot.
(>BLOCK I.En.)
Inadvertent Energi-
sation
SP
*
*
LED BI
BO
05541 Inadvert. Energ. prot. is swiched OFF
(I.En. OFF)
Inadvertent Energi-
sation
OUT
ON
OF
F
*
LED
BO
72
31
1
GI
05542 Inadvert. Energ. prot. is BLOCKED
(I.En. BLOCKED)
Inadvertent Energi-
sation
OUT
ON
OF
F
ON
OFF
LED
BO
72
32
1
GI
F.No.
Description
Function
Type
of
Infor-
matio
n
Log-Buffers
Configurable in Matrix
IEC 60870-5-103
E
v
en
t
L
o
g
On
/O
ff
T
rip
(F
au
lt)
L
o
g
On
/Of
f
Gr
o
u
n
d
F
a
u
lt
L
o
g
O
n
/Of
f
M
a
rk
e
d
in
Osc
ill.
Reco
rd
LED
Bi
n
a
ry
In
p
u
t
Fun
ct
io
n
K
e
y
B
ina
ry
O
u
tp
ut
C
h
at
te
r
B
lo
c
k
in
g
Ty
pe
In
fo
rm
a
ti
on
-N
o
D
a
ta
Un
it
(A
SDU)
G
e
ne
ra
l
In
te
rr
oga
ti
o
n