A Appendix
596
7UT613/63x Manual
C53000-G1176-C160-2
235.2125
Function $00 TRIP Delay Time
Out ($00 Time Out)
Flx
OUT
*
*
*
LED
BO
235.2126
Function $00 TRIP ($00 TRIP)
Flx
OUT
*
ON
*
LED
BO
235.2128
Function $00 has invalid settings
($00 inval.set)
Flx
OUT
ON
OFF
*
*
LED
BO
235.2701
>Function $00 block TRIP L12
(>$00 Blk Trip12)
Flx
SP
ON
OFF
on off
*
LED BI
BO
235.2702
>Function $00 block TRIP L23
(>$00 Blk Trip23)
Flx
SP
ON
OFF
on off
*
LED BI
BO
235.2703
>Function $00 block TRIP L31
(>$00 Blk Trip31)
Flx
SP
ON
OFF
on off
*
LED BI
BO
235.2704
Function $00 Pick-up L12 ($00
Pick-up L12)
Flx
OUT
*
ON
OFF
*
LED
BO
235.2705
Function $00 Pick-up L23 ($00
Pick-up L23)
Flx
OUT
*
ON
OFF
*
LED
BO
235.2706
Function $00 Pick-up L31 ($00
Pick-up L31)
Flx
OUT
*
ON
OFF
*
LED
BO
236.2127
BLOCK Flexible Function (BLK.
Flex.Fct.)
P.System Data 2
IntSP
on
off
*
*
LED
BO
251
Broken wire detected (Broken
wire)
Supervision
OUT
ON
OFF
*
*
LED
BO
264
Failure: RTD-Box 1 (Fail: RTD-
Box 1)
Supervision
OUT
ON
OFF
*
*
LED
BO
135
208
1
Yes
267
Failure: RTD-Box 2 (Fail: RTD-
Box 2)
Supervision
OUT
ON
OFF
*
*
LED
BO
135
209
1
Yes
272
Set Point Operating Hours (SP.
Op Hours>)
SetPoint(Stat)
OUT
ON
OFF
*
*
LED
BO
135
229
1
Yes
301
Power System fault
(Pow.Sys.Flt.)
P.System Data 2
OUT
ON
OFF
ON
*
135
231
2
Yes
302
Fault Event (Fault Event)
P.System Data 2
OUT
*
ON
*
135
232
2
Yes
311
Fault in configuration / setting
(FaultConfig/Set)
P.System Data 2
OUT
ON
OFF
*
*
LED
BO
312
Gen.err.: Inconsistency
group/connection (GenErrGroup-
Conn)
P.System Data 2
OUT
ON
*
*
LED
BO
313
Gen.err.: Sev. earth-CTs with
equal typ (GenErrEarthCT)
P.System Data 2
OUT
ON
*
*
LED
BO
314
Gen.err.: Number of sides / mea-
surements (GenErrSidesMeas)
P.System Data 2
OUT
ON
*
*
LED
BO
320
Warn: Limit of Memory Data ex-
ceeded (Warn Mem. Data)
Device
OUT
ON
OFF
*
*
LED
BO
321
Warn: Limit of Memory Parameter
exceeded (Warn Mem. Para.)
Device
OUT
ON
OFF
*
*
LED
BO
321.2404
>BLOCK 3I0 time overcurrent 2
(>BLK 3I0 O/C 2)
3I0 O/C 2
SP
*
*
*
LED BI
BO
321.2411
Time Overcurrent 3I0-2 is OFF
(O/C 3I0-2 OFF)
3I0 O/C 2
OUT
ON
OFF
*
*
LED
BO
321.2412
Time Overcurrent 3I0-2 is
BLOCKED (O/C 3I0-2 BLK)
3I0 O/C 2
OUT
ON
OFF
ON
OFF
*
LED
BO
321.2413
Time Overcurrent 3I0-2 is
ACTIVE (O/C 3I0-2 ACT)
3I0 O/C 2
OUT
ON
OFF
*
*
LED
BO
321.2425
Time Overcurrent 3I0-2 picked up
(O/C 3I0-2 PU)
3I0 O/C 2
OUT
*
ON
OFF
*
LED
BO
321.2491
O/C 3I0-2: Not available for this
object (O/C 3I0-2 n/a)
3I0 O/C 2
OUT
ON
*
*
LED
BO
No.
Description
Function
T
y
pe of I
n
form
at
io
n
Log Buffers
Configurable in Matrix
IEC 60870-5-103
Ev
ent Log
O
N
/O
FF
T
rip (
F
aul
t)
Log On/
O
ff
G
round
Fault Log ON/
O
FF
M
a
rk
e
d
i
n
O
s
ci
ll.
Re
c
o
rd
LED
B
ina
ry
I
n
pu
t
Function
Key
Rela
y
Chatte
r Suppr
e
ssion
Ty
p
e
In
form
ati
on Nu
mbe
r
Dat
a
Un
it
Ge
ne
ra
l Int
e
rro
ga
ti
on
Summary of Contents for SIPROTEC 7UT613 series
Page 16: ...Contents 16 7UT613 63x Manual C53000 G1176 C160 2 Literature 631 Glossary 623 Index 633 ...
Page 30: ...1 Introduction 30 7UT613 63x Manual C53000 G1176 C160 2 ...
Page 506: ...A Appendix 506 7UT613 63x Manual C53000 G1176 C160 2 7UT633 D E ...
Page 508: ...A Appendix 508 7UT613 63x Manual C53000 G1176 C160 2 7UT633 P Q ...
Page 510: ...A Appendix 510 7UT613 63x Manual C53000 G1176 C160 2 7UT635 D E ...
Page 512: ...A Appendix 512 7UT613 63x Manual C53000 G1176 C160 2 7UT635 P Q ...
Page 515: ...A 2 Terminal Assignments 515 7UT613 63x Manual C53000 G1176 C160 2 7UT633 B ...
Page 517: ...A 2 Terminal Assignments 517 7UT613 63x Manual C53000 G1176 C160 2 7UT633 N ...
Page 519: ...A 2 Terminal Assignments 519 7UT613 63x Manual C53000 G1176 C160 2 7UT635 B ...
Page 521: ...A 2 Terminal Assignments 521 7UT613 63x Manual C53000 G1176 C160 2 7UT635 N ...
Page 622: ...A Appendix 622 7UT613 63x Manual C53000 G1176 C160 2 ...
Page 632: ...Literature 632 7UT613 63x Manual C53000 G1176 C160 2 ...