Appendix
A.8 Information List
SIPROTEC, 7SD5, Manual
C53000-G1176-C169-5, Release date 02.2011
717
1356
E/F 3I0> PICKED UP (EF 3I0>
Pickup)
Earth Fault O/C
OUT
*
on
*
LED
BO
1357
E/F 3I0p PICKED UP (EF 3I0p
Pickup)
Earth Fault O/C
OUT
*
on
*
LED
BO
1358
E/F picked up FORWARD (EF
forward)
Earth Fault O/C
OUT
*
on
*
LED
BO
166
58
2
No
1359
E/F picked up REVERSE (EF re-
verse)
Earth Fault O/C
OUT
*
on
*
LED
BO
166
59
2
No
1361
E/F General TRIP command (EF
Trip)
Earth Fault O/C
OUT
*
*
*
LED
BO
166
61
2
No
1362
Earth fault protection: Trip 1pole
L1 (E/F Trip L1)
Earth Fault O/C
OUT
*
on
*
LED
BO
166
62
2
Yes
1363
Earth fault protection: Trip 1pole
L2 (E/F Trip L2)
Earth Fault O/C
OUT
*
on
*
LED
BO
166
63
2
Yes
1364
Earth fault protection: Trip 1pole
L3 (E/F Trip L3)
Earth Fault O/C
OUT
*
on
*
LED
BO
166
64
2
Yes
1365
Earth fault protection: Trip 3pole
(E/F Trip 3p)
Earth Fault O/C
OUT
*
on
*
LED
BO
166
65
2
Yes
1366
E/F 3I0>>> TRIP (EF 3I0>>>
TRIP)
Earth Fault O/C
OUT
*
on
*
LED
BO
166
66
2
No
1367
E/F 3I0>> TRIP (EF 3I0>> TRIP) Earth Fault O/C
OUT
*
on
*
LED
BO
166
67
2
No
1368
E/F 3I0> TRIP (EF 3I0> TRIP)
Earth Fault O/C
OUT
*
on
*
LED
BO
166
68
2
No
1369
E/F 3I0p TRIP (EF 3I0p TRIP)
Earth Fault O/C
OUT
*
on
*
LED
BO
166
69
2
No
1370
E/F Inrush picked up (EF Inrush-
PU)
Earth Fault O/C
OUT
*
on off
*
LED
BO
166
70
2
No
1371
E/F Telep. Carrier SEND signal,
Phase L1 (EF Tele SEND L1)
Teleprot. E/F
OUT
on
on
*
LED
BO
166
71
1
No
1372
E/F Telep. Carrier SEND signal,
Phase L2 (EF Tele SEND L2)
Teleprot. E/F
OUT
on
on
*
LED
BO
166
72
1
No
1373
E/F Telep. Carrier SEND signal,
Phase L3 (EF Tele SEND L3)
Teleprot. E/F
OUT
on
on
*
LED
BO
166
73
1
No
1374
E/F Telep. Block: carrier STOP
signal L1 (EF Tele STOP L1)
Teleprot. E/F
OUT
*
on
*
LED
BO
166
74
2
No
1375
E/F Telep. Block: carrier STOP
signal L2 (EF Tele STOP L2)
Teleprot. E/F
OUT
*
on
*
LED
BO
166
75
2
No
1376
E/F Telep. Block: carrier STOP
signal L3 (EF Tele STOP L3)
Teleprot. E/F
OUT
*
on
*
LED
BO
166
76
2
No
1380
E/F Teleprot. ON/OFF via BI (EF
TeleON/offBI)
Teleprot. E/F
IntSP
on
off
*
*
LED
BO
1381
E/F Teleprotection is switched
OFF (EF Telep. OFF)
Teleprot. E/F
OUT
on
off
*
*
LED
BO
166
81
1
Yes
1384
E/F Telep. Carrier SEND signal
(EF Tele SEND)
Teleprot. E/F
OUT
on
on
*
LED
BO
166
84
2
No
1386
E/F Telep. Transient Blocking (EF
TeleTransBlk)
Teleprot. E/F
OUT
*
on
*
LED
BO
166
86
2
No
1387
E/F Telep. Unblocking: FAILURE
Channel 1 (EF TeleUB Fail1)
Teleprot. E/F
OUT
on
off
*
*
LED
BO
166
87
1
Yes
1388
E/F Telep. Unblocking: FAILURE
Channel 2 (EF TeleUB Fail2)
Teleprot. E/F
OUT
on
off
*
*
LED
BO
166
88
1
Yes
1389
E/F Telep. Blocking: carrier STOP
signal (EF Tele BL STOP)
Teleprot. E/F
OUT
*
on
*
LED
BO
166
89
2
No
1390
E/F Tele.Blocking: Send signal
with jump (EF Tele BL Jump)
Teleprot. E/F
OUT
*
*
*
LED
BO
166
90
2
No
1401
>BF: Switch on breaker fail pro-
tection (>BF on)
Breaker Failure
SP
*
*
*
LED BI
BO
No.
Description
Function
Type
of In-
for-
matio
n
Log Buffers
Configurable in Matrix
IEC 60870-5-103
Ev
ent Log
O
N
/O
FF
T
rip (
F
aul
t)
Log On/
O
ff
G
round
Fault Log ON/
O
FF
M
a
rk
e
d
i
n
O
s
ci
ll.
Re
c
o
rd
LED
B
ina
ry
I
n
pu
t
Function
Key
Rela
y
Chatte
r Suppr
e
ssion
Ty
p
e
In
form
ati
on Nu
mbe
r
Dat
a
Un
it
Ge
ne
ra
l Int
e
rro
ga
ti
on