Appendix
A.10 Measured Values
SIPROTEC, 7SD5, Manual
C53000-G1176-C169-5, Release date 02.2011
747
A.10
Measured Values
No.
Description
Function
IEC 60870-5-103
Configurable in Matrix
Ty
p
e
Inf
o
rm
a
tion
Num
b
e
r
Com
p
a
ti
b
il
it
y
Da
ta
U
n
it
Po
si
ti
on
CFC
Cont
ro
l D
is
p
la
y
D
e
fa
u
lt D
is
p
la
y
-
Upper setting limit for IL1dmd (IL1dmd>)
Set Points(MV)
-
-
-
-
-
CFC
CD
DD
-
Upper setting limit for IL2dmd (IL2dmd>)
Set Points(MV)
-
-
-
-
-
CFC
CD
DD
-
Upper setting limit for IL3dmd (IL3dmd>)
Set Points(MV)
-
-
-
-
-
CFC
CD
DD
-
Upper setting limit for I1dmd (I1dmd>)
Set Points(MV)
-
-
-
-
-
CFC
CD
DD
-
Upper setting limit for Pdmd (|Pdmd|>)
Set Points(MV)
-
-
-
-
-
CFC
CD
DD
-
Upper setting limit for Qdmd (|Qdmd|>)
Set Points(MV)
-
-
-
-
-
CFC
CD
DD
-
Upper setting limit for Sdmd (Sdmd>)
Set Points(MV)
-
-
-
-
-
CFC
CD
DD
-
Lower setting limit for Power Factor (PF<)
Set Points(MV)
-
-
-
-
-
CFC
CD
DD
601
I L1 (IL1 =)
Measurement
134
129
No
9
1
CFC
CD
DD
602
I L2 (IL2 =)
Measurement
134
129
No
9
2
CFC
CD
DD
603
I L3 (IL3 =)
Measurement
134
129
No
9
3
CFC
CD
DD
610
3I0 (zero sequence) (3I0 =)
Measurement
134
129
No
9
14
CFC
CD
DD
611
3I0sen (sensitive zero sequence) (3I0sen=) Measurement
-
-
-
-
-
CFC
CD
DD
612
IY (star point of transformer) (IY =)
Measurement
-
-
-
-
-
CFC
CD
DD
613
3I0par (parallel line neutral) (3I0par=)
Measurement
-
-
-
-
-
CFC
CD
DD
619
I1 (positive sequence) (I1 =)
Measurement
-
-
-
-
-
CFC
CD
DD
620
I2 (negative sequence) (I2 =)
Measurement
-
-
-
-
-
CFC
CD
DD
621
U L1-E (UL1E=)
Measurement
134
129
No
9
4
CFC
CD
DD
622
U L2-E (UL2E=)
Measurement
134
129
No
9
5
CFC
CD
DD
623
U L3-E (UL3E=)
Measurement
134
129
No
9
6
CFC
CD
DD
624
U L12 (UL12=)
Measurement
134
129
No
9
10
CFC
CD
DD
625
U L23 (UL23=)
Measurement
134
129
No
9
11
CFC
CD
DD
626
U L31 (UL31=)
Measurement
134
129
No
9
12
CFC
CD
DD
627
Uen (Uen =)
Measurement
-
-
-
-
-
CFC
CD
DD
631
3U0 (zero sequence) (3U0 =)
Measurement
-
-
-
-
-
CFC
CD
DD
632
Measured value Usy2 (Usy2=)
Measurement
-
-
-
-
-
CFC
CD
DD
633
Ux (separate VT) (Ux =)
Measurement
-
-
-
-
-
CFC
CD
DD
634
U1 (positive sequence) (U1 =)
Measurement
-
-
-
-
-
CFC
CD
DD
635
U2 (negative sequence) (U2 =)
Measurement
-
-
-
-
-
CFC
CD
DD
636
Measured value U-diff (Usy1- Usy2) (Udiff =) Measurement
130
1
No
9
2
CFC
CD
DD
637
Measured value Usy1 (Usy1=)
Measurement
130
1
No
9
3
CFC
CD
DD
638
Measured value Usy2 (Usy2=)
Measurement
130
1
No
9
1
CFC
CD
DD
641
P (active power) (P =)
Measurement
134
129
No
9
7
CFC
CD
DD
642
Q (reactive power) (Q =)
Measurement
134
129
No
9
8
CFC
CD
DD
643
Power Factor (PF =)
Measurement
134
129
No
9
13
CFC
CD
DD
644
Frequency (Freq=)
Measurement
134
129
No
9
9
CFC
CD
DD
645
S (apparent power) (S =)
Measurement
-
-
-
-
-
CFC
CD
DD
646
Frequency fsy2 (F-sy2 =)
Measurement
130
1
No
9
4
CFC
CD
DD
647
Frequency (difference line-bus) (F-diff=)
Measurement
130
1
No
9
5
CFC
CD
DD
648
Angle difference (
ϕ
-diff=)
Measurement
130
1
No
9
6
CFC
CD
DD
649
Frequency fsy1 (F-sy1 =)
Measurement
130
1
No
9
7
CFC
CD
DD
679
U1co (positive sequence, compounding)
(U1co=)
Measurement
-
-
-
-
-
CFC
CD
DD
684
U0 (zero sequence) (U0 =)
Measurement
-
-
-
-
-
CFC
CD
DD